background image

1

GB

TECHNICAL DATA.................................................................................................................................
APPLICATION.......................................................................................................................................
WARNING............................................................................................................................................
GENERAL SAFETY..................................................................................................................................
SAFETY INSTRUCTION FOR SANDER.....................................................................................................
SYMBOLS.............................................................................................................................................
OPERATING INSTRUCTION...................................................................................................................
CLEANING AND MAINTENENCE...........................................................................................................
ENVIRONMENT....................................................................................................................................
TROUBLE SHOOTING............................................................................................................................

Contents

TECHNICAL DATA

Model

MPFS200

code

111-0510

Voltage
Rated power input

200W

230-240V~50Hz

No-load speed

12000/min

Sanding plate size

92×187mm

Base plate

Aluminum

Cable

PVC

Cable length

1.8M

Weight according to EPTA-Procedure 01/2003

1.7 KG

Noise/Vibra

nforma

LpA sound pressure level

80.7 dB(A)

LWA sound power level

91.7 dB(A)

Uncertainty

3 dB(A)

Vibra

value

7.96 m/s²

Uncertainty

1.5 m/s²

The vibra

 emission level given in this informa

 sheet has been measured in accordance with a 

standardised test given in EN 62841,2012/19/EU and may be used to compare one tool with another. It may 

be used for a preliminary assessment of exposure.

The declared vibra

 emission level represents the main applica

s of the tool. However if the tool is 

used for di

erent applica

 with di

erent accessories or poorly maintained, the vibra

 emission may 

di

er. This ma

y signifi

cantly increase the exposure level over the total working period.

An es

a

 of the level of exposure to vibra

 should also take into account the 

 when the tool is 

switched o

 or when it is running but not actually doing the job. This may 

signifi

cantly reduce the exposure 

level over the total working period.

1
2
2
2

3
4

4
5
5

6

1

2

3

Summary of Contents for 111-0510

Page 1: ...shing sander 1 6 GB Ponceuse 1 3 feuille vibrante 7 13 FR Lijadora de acabados de 1 3 hoja 14 20 ES 21 27 RU www maxpro tools com 2021 04 MPFS200 EN 62841 1 2015 EN 62841 2 4 2014 2006 42 EC 2014 30 E...

Page 2: ...ission level given in this informa sheet has been measured in accordance with a standardised test given in EN 62841 2012 19 EU and may be used to compare one tool with another It may be used for a pre...

Page 3: ...d for appropriate conditions will reduce personal injuries c Prevent unintentional starting Ensure the switch is in the o position before connecting to power source and or battery pack picking up or c...

Page 4: ...ner the grain It is important to use the right paper for each job For rough sanding use grain sizes up to 80 f wood as larch pine or spruce use papers from 60grit to 150grit For dense hardwood as beec...

Page 5: ...rer Ring re caused by shortcircuit in rotor winding shortcircuit Check or replace rotor by repairer Ring re caused by shortcircuit in commutator segment Check or replace rotor by repairer Running spee...

Page 6: ...s curit et les ins Ne pas suivre ces av nts et ces ins pourraient entra ner un choc lectrique un incendie et ou des blessures graves Assurez vous que la tension correspond aux donn es inscrites sur la...

Page 7: ...s se coincent moins souvent et peuvent tre guid s plus facilement g U sez les ou s lectroporta fs les accessoires les ou s monter etc conform ment ces ins Tenez compte galement des c de travail et du...

Page 8: ...la surface Pon age Appliquez seulement sous une pression mod r e dans une machine Trop de pression conduira un blocage du m canisme et g chera le r sultat Une pression excessive risque de surchau er l...

Page 9: ...incorrect de papier d meri Remplacer le papier d meri DATOS T CNICOS APLICACI N ADVERTENCIA INSTRUCCIONES GENERALES DE SEGURIDAD INSTRUCCIONES DE SEGURIDAD PARA LIJADORAS S MBOLOS INSTRUCCI N DE OPER...

Page 10: ...jado del calor aceite esquinas cortantes opiezas m viles Los cables de red da ados oenredados pueden provocar una descarga el ctrica e Al trabajar con la herramienta el ctrica en laintemperie e solame...

Page 11: ...e los o dos Advertencia Ponerse m scara de polvos Aislamiento doble No debe disponer los aparatos viejos en la basura dom s ca Ponerse gafas de seguridad Mantenga sus manos y pies fuera de todas las a...

Page 12: ...la fuente de alimentaci n Desgaste total de las escobillas de carb n Cambiar las escobillas de carb n por un profesional El interrupt contacto Comprobar y cambiar el interruptor por un profesional La...

Page 13: ...21 RU MPFS200 111 0510 230 240V 50Hz 200W 12000 min 92 187mm PVC 1 8M 1 7 KG LpA 80 7 dB A LWA 91 7 dB A 3 dB A 7 96 m s 1 5 m s EN 62841 2012 19 EU 21 22 22 22 24 25 25 26 26 26...

Page 14: ...22 23 RU RU 85 A 1 a b c 2 a b c d e f 3 a b c d e f g 4 a b c d e f...

Page 15: ...24 25 RU RU g 5 a p 16 p p x p MAXPRO p p p x p p p p p p p p 230 240 220 p p x 16 p p p p p 80 dB A x p x p p px p p p p x p p p p p x p p p p p p p p p 1 40 60 80 60 150 220 2...

Page 16: ...26 27 RU RU 3 1 ON OFF 2 ON OFF ON OFF ON OFF 2002 96...

Reviews: