![Maxon IDX 56 User Manual Download Page 47](http://html1.mh-extra.com/html/maxon/idx-56/idx-56_user-manual_1745158047.webp)
Maintenance
General Rules
IDX 56 User Manual
mmag | 2020-04 | rel9398
6-47
6
MAINTENANCE
6.1
General Rules
Prior commencing any work
Before you commence with any work, be aware of the necessary safety precautions (
page 5) and strictly
follow them.
6.2
Periodic Inspection
The IDX drive as a whole and its individual parts are maintenance-free.
If you perform main-
tenance on adjacent
components.
The adjacent components, such as motor mount, fixations, couplings and output elements, electrical sup-
ply, etc. are customer-made parts. For the point of time for their maintenance and repair consult the relevant
instructions. Thereby, also consider the following items.
Table 6-36
Maintenance plan
WARNING
Risk of injury
The attempt to open the device can lead to serious injury
• The device does not contain any user-serviceable parts.
• Do not attempt to open the device.
• Any attempt to open the device will lead to permanent damage of the device.
• Any attempt to open the device will void any possible warranty.
When?
Where?
What?
Every 500 service hours
Motor mount
Check bolted connection between the drive’s
fixation flange and the motor mount for tight fit.
Tighten again to the specified torque if necessary.
Coupling
Check for tight fit and correct alignment. Realign
and/or tighten again if necessary.
Cable connectors
Check for tight fit. Tighten again if necessary.
Connection cables
Check cables for signs of wear, tear, or damage.
Check for correct routing. Restore original
conditions if necessary.
Every 12 months if not
in use
or
During long-term stor-
age
or
After extended stand-
still periods
Brake
Check for proper function
Storage location
Check for proper conditions at the storage location
(
page 6-48). Reestablish correct conditions if