Specifications
Standards
IDX 56 User Manual
mmag | 2020-04 | rel9398
2-19
2.6
Standards
The described device has been successfully tested for compliance with the below listed standards.
In practical terms, only the complete system (the fully operational equipment comprising all individual com-
ponents, such as motor, controller, power supply unit, EMC filter, cabling etc.) can undergo an EMC test to
ensure interference-free operation.
EMV compliance
The device’s compliance with the mentioned standards does not imply its compliance within the final, ready
to operate setup. In order to achieve compliance of your operational system, you must perform EMC testing
of the involved equipment as a whole.
Table 2-7
Standards
Electromagnetic compatibility
Generic
IEC/EN 61000-6-2
Immunity for industrial environments
IEC/EN 61000-6-4
Emission standard for industrial environments
Applied
IEC/EN 55011
(CISPR11)
Radio disturbance characteristics for scientific and medical
equipment
IEC/EN 61000-4-2
Electrostatic discharge immunity test 8kV/6kV
IEC/EN 61000-4-3
Radiated, radio-frequency, electromagnetic field immunity test
>10 V/m
IEC/EN 61000-4-4
Electrical fast transient/burst immunity test ±2 kV
IEC/EN 61000-4-6
Immunity to conducted disturbances, induced by radio-
frequency fields 10 Vrms
IEC/EN 61000-4-8
Power frequency magnetic field 30 A/m
Others
Environment
IEC/EN 60068-2-6
Environmental testing – Test Fc: Vibration (sinusoidal, 10…500
Hz, 20 m/s
2
)
MIL-STD-810F
Random transport (10…500 Hz up to 2.53 g
rms
)
IEC/EN 60529
(1991+A1:2000+A2:2013)
Degrees of protection provided by enclosures (IP Code)
Safety
UL File Number
Unassembled printed circuit board E76251