![Maxon IDX 56 User Manual Download Page 32](http://html1.mh-extra.com/html/maxon/idx-56/idx-56_user-manual_1745158032.webp)
Electrical Installation
Connections
IDX 56 User Manual
4-32
mmag | 2020-04 | rel9398
WIRING EXAMPLES
Table 4-22
Digital output, internally supplied
Figure 4-16
DigOUT1, internally supplied (analogously valid for DigOUT2)
Table 4-23
Digital output, externally supplied
Continued on next page.
Figure 4-17
DigOUT1, externally supplied (analogously valid for DigOUT2)
Continued on next page.
DigOUT (internally supplied)
Output voltage
U
Out
= approx. 19 V
Max. load current
I
Load
≤
35 mA
DigOUT (externally supplied)
Input voltage
+V
I/O
Max. load current
250 mA
Max. voltage drop
0.5 V @ 250 mA