Specifications
Thermal Data
maxon motor control
EPOS4 Positioning Controller
Document ID: rel5977
2-13
EPOS4 Module/Compact 50/8 Hardware Reference
Edition: February 2016
© 2016 maxon motor. Subject to change without prior notice.
2.2
Thermal Data
2.2.1
Derating of Output Current
Figure 2-3
Derating output current
2.2.2
Power Dissipation and Efficiency
Figure 2-4
Power dissipation and efficiency
2.3
Limitations
Table 2-5
Limitations
Protection functionality
Switch-off threshold
Recovery threshold
Undervoltage
8.0 V
8.5 V
Overvoltage
58 V
56 V
Overcurrent
40 A
—
Thermal overload
100 °C
90 °C