11
MOTO
R
Power In
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
MATRIX
BOARD
ALARM
BATTER
Y
PAC
K
LIMIT
SWITCH
MOTO
R
INPUTS
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
ON/OFF
Battery
E
F
1/2
Battery Voltage
Replace
Battery
TEST
Battery
Battery IN
Error
MAX BC-7
Battery Module
A remote power supply is for installations where it is too costly or difficult to trench a 115/230 VAC power line to the operator
but instead run a low voltage power line to the operator. A
MAX Magic Box
Kit (sold separately) is required to remotely install a
Remote MAX Megatron Toroid box.
Install the
MAX Magic Box
near the 115 VAC or 230 VAC input AC power source, up to 1000 ft away from gate operator.
NOTE:
A
MAX Magic Box
kit is required for
EACH
gate operator when using dual gate operators.
Concrete Pad
24VDC Low Voltage Power
Conduit
Ground Level
At Gate
Operator
optional remote power supply kit - max magic box
installation
Operator
MAX Magic Box
Near Power Source
115/230 VAC Power Source
Distance - See table below
2-Wires, 24VDC Low Voltage Power
Gate Weight
Max Wire Distance - Wire Gauge
500 ft - 12AWG
500 ft - 10AWG
1400 lbs
2200 lbs
1000 ft - 10AWG
1000 ft - 8AWG
At MAX Magic Box
230V
AC
ON
PO
WE
R
OFF
MAX PS-24
PO
WE
R SU
PPL
Y
FU
SE
7 A
MP
IN
Ma
de
in
U
SA
Se
lect
In
put
Volt
age:
115
VAC
or 23
0V
AC
di
sco
nne
ct
pow
er b
efo
re
se
rv
icin
g un
it
W
AR
NI
NG
W
AR
NIN
G
HI
GH
H
IG
H
VO
LT
AG
E
VO
LT
AG
E
!
wa
rranty
VOIDED
if la
be
l is
RE
MO
VED
Input Power
To
Ope
rator
2
4 VDC
Remote T
oroid
15 Amp Bo
x
See page 20 for
MAX Magic Box
wiring instructions.
Inpu
t AC
Power
Conduit
not suppl
ied
24VDC
Lo
w
Vo
ltag
e
Power
Low Vo
ltage
High Vo
ltage
Power/Solar In
Connector
Wire
Nuts
MAX Magic Box Kit
230V
AC
ON
PO
WE
R
OF
F
MA
X P
S-2
4
PO
WE
R S
UP
PL
Y
FU
SE
7 A
MP
IN
Ma
de
in
USA
Selec
t Input V
ol
tage:
115
VA
C or
230V
AC
dis
con
ne
ct
po
we
r b
ef
ore
ser
vic
in
g u
nit
WA
RNIN
G
W
AR
NIN
G
H
IGH
H
IG
H
VO
LT
AG
E
VO
LT
AG
E
!
warranty
VOID
ED
if la
bel is
RE
MOVED
Remote
Toroid
15 Amp Bo
x
Cove
r
Cabinet
Sold Separately