background image

27

matrix 1

Turned OFF -

 

Close timer

 will close the gate. If an in-ground 

safety

 or 

exit

 loop 

gets activated during the close cycle, gate will 

REVERSE

 to the open position.

Turned ON -

 (In-ground loops required) Gate will close after 

all the in-ground 

loops have been cleared

 no matter how long the close timer is set for. If an 

in-ground safety loop gets activated during the close cycle, gate will 

REVERSE

 

to the open position.

Turned ON -

 (In-ground loops required) Gate will close after all the in-ground 

loops have been cleared no matter how long the close timer is set for. When an 
in-ground safety loop gets activated during the close cycle, gate will 

PAUSE

 and 

NOT

 reopen. When loop is cleared, gate will continue to close 

preventing 

UNAUTHORIZED entry.

anti tailgate

Single pass anti-tailgate

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM
GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

SAFETY

ANTI

TAILGATE

OFF

ON

AUTHORIZED Vehicle

UNAUTHORIZED Vehicle

1

2

When last Safety Loop is cleared, gate will close.

NOTE:

 If a 

VALID

 open command is received at this 

point, gate will stop and reopen.

Safety Loop gets activated and 

PAUSES

 the closing gate.

Gate will 

NOT

 reopen. Vehicle 

MUST

 back up for loop to 

clear, then gate continues to close. 

NO unauthorized entry

NO VALID

 open command.

OFF

OFF

ON

ON

Single Pass Anti-Tailgate

Radio Safety Pause

Mode 0

Gate in Motion Alarms

ON

OFF

ON

OFF

ON

OFF

Mode 1

Mode 1

ON

OFF

Motion Alarm sounds before gate moves and continues until gate stops

Motion Alarms OFF

Beeper Alert sounds in Battery Back-Up Mode while gate is in motion

Beeper Alert OFF

Mode 0

When turned “ON”; After a vehicle clears the Safety Loop, a closing
gate will PAUSE if a second vehicle attempts to tailgate. The second
vehicle must then back off the safety loop for the gate to continue
closing. A new radio signal will open the gate.

When turned "ON" a moving gate will pause if a radio input signal is
received. The next radio signal causes the gate to continue in the
original direction.

MADE IN USA

WWW.Max.US.com

OFF

ON

VALID

 open command was given.

UNAUTHORIZED Vehicle Approaches

NO VALID

 open command is given.

Vehicle is attempting to activate safety loop
before the gate’s close cycle is complete,
expecting gate to reopen.

SAFETY LOOP

CENTER LOOP

SAFETY LOOP

INSIDE

Property

OUTSIDE

Property

CENTER LOOP

SAFETY LOOP

SAFETY LOOP

MATRIX 1 Back

- Gate Pauses -

- Gate Pauses -

LED stays ON

when Anti Tailgate

is ON

Summary of Contents for Max Megatron 1400

Page 1: ...rushless DC Swing Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Bi Parting Gates ONLY Single or Bi Parting Gates Single or Bi Parting Gat...

Page 2: ......

Page 3: ...Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Tailgate Single Pass Anti Tailgate Radio Receiver Radio Safety Pause Gate in Motion Alarm...

Page 4: ...1600lbs 12 ft gate per operator 90 Opening Time MAX Megatron 1400 1400HP 2200 16 selectable speeds from approximately 11 5 sec to 20 sec depending on the weight and length of the gate MAX Megatron FAS...

Page 5: ...rsonnel SECURITY AUTHORIZED PERSONNEL ONLY ul 325 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivale...

Page 6: ...art of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to preve...

Page 7: ...t the gate operator from accidentally closing on vehicles in the gate s closing path and entrapment M ovin g Gate Can Cause Serious In ju ry or Death KE EP CL EA R Ga te may mov e at an y tim e withou...

Page 8: ...mper NO COM GND T amper IN OFF OFF ON EXIT P ARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OF...

Page 9: ...ION CENT ER REVE RSE SENS ITIVIT Y MOTO R OVER LOAD NO LIMIT SWIT CH CLAM P SLIPP ING MIN MAX 12VD C GND 24VD C GND MAX MIN OFF SAFET Y LEAVE OPEN LEAVE CLOS ED MADE in USA OPEN 1 TIME 2Sec 1 5Se c C...

Page 10: ...should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending YES YES NO NO Gate Bracket Support Bar Too High Not Long Enough Support Bar MOTOR Power In...

Page 11: ...D MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOT...

Page 12: ...com Made in USA BATTERY PACK TO MOTOR CONTROLLER PhotoCell Edge UL Entrap 1 2 Limit SW ON LINE MATRIX JOG LEFT JOG RIGHT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Moto...

Page 13: ...tely install a Remote MAX Megatron Toroid box Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source up to 1000 ft away from gate operator NOTE A MAX Magic Box kit is required for...

Page 14: ...IMIT 2 4 V GND UL ALARM 12V ALARM RET RESET GND GA TE T AMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELA Y PRIMARY GA TE SAFETY CENTER EXIT OPEN MAX GA TE SPEED STOP CLOSE ANTI T AILGA TE CLOSE TIMER...

Page 15: ...onitored Normally Closed Type IMPORTANT Sensing edges MUST be Monitored 10K Normally Closed Type and a GEM 104 module MUST be installed Closed Gate Max 10K Mini Sensing Edge N C Hinge Area End of Gate...

Page 16: ...ired in series MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED S...

Page 17: ...FETY CENT ER EXIT OP EN MAX GA TE SP EED STOP CLOS E AN TI TAILGA TE CLOS E TIMER PO SITION RE CO RD ER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTER Y BA CK UP MOD E MATRIX 1 PH OT OC ELL ED GE 1 ED...

Page 18: ...Battery Button Press to show amount of battery power available when using battery power ONLY Battery voltage LEDs will light respectively Battery IN Error LED Lights when there is a battery connectio...

Page 19: ...t End of Gate Options GND C P h o to C e ll E d g e U L E n tr a p 1 2 L im it S W O N L IN E M A T R IX J O G L E F T J O G R I G H T J o g L T J o g R T G N D E d g e 1 E d g e 2 P h o to C e ll E R...

Page 20: ...AD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE E TIMER CENTER MAX MIN OFF SAFETY POSITION CORDER OPEN STOP CLOSE MOTOR MOTION Inputs MUST be LEARNED to MONI...

Page 21: ...rotec tio n co ntre les ris qu es d ince nd ie utilise r un fusible de m m es type et ca ract ristiq ue s no minales AC IN Power LED M A X M e g a t r o n T o r o i d B o x disconnect power before ser...

Page 22: ...Polarity Matters Remove the Remote Toroid 15 Amp connector from the BC 7 battery module POWER SOLAR IN port Plug the Magic Box POWER SOLAR IN connector into the POWER SOLAR IN port NOTE A MAX Magic Bo...

Page 23: ...e BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER w w w M a x U S c o m BATTERY IN POWER SOLAR IN Refer to Solar application guide Max Solar Power Kit Sold separately Connect to PO...

Page 24: ...ge Re pla ce Ba tte ry TE ST Ba tte ry Ba tte ry IN Err or MAX BC 7 Ba tte ry Mo du le B A T T E R Y IN P O W E R S O L A R IN P O W E R IN B a tt e ry P a c k T O M O T O R C O N T R O L L E R w w w...

Page 25: ...t 2 or 3 3 Press an d HOLD the OPEN STO P bu tto ns at the sa me tim e on Matrix 1 un til be ep is he ard learn mod e be gins Le arn mod e lasts for 5 min indica ted by be ep ing 4 LE Ds WILL be ON f...

Page 26: ...le attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gate When turned ON a moving gate will pause if a radio...

Page 27: ...Dual Gates See page 34 See page 28 Emergency OPEN Overrides gate disable switch MAX OPEN Overrides gate disable switch 4 Wire Radio 3 Wire Radio Emergency Security Devices Normal Opening Devices Norm...

Page 28: ...rements for each successive click up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RE...

Page 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Page 30: ...BATTERY IN USE POWER GATE STATUS GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLU...

Page 31: ...when there is an error with the corresponding loop detector NOTE Reno H2 detector always blinks steadily during normal operation MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESE...

Page 32: ...MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTER...

Page 33: ...FF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE...

Page 34: ...TATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Power GND GND N O Com MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK...

Page 35: ...MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMI...

Page 36: ...ONITO R se ns ors To LE AR N inpu ts 1 MONITO RE D Se ns ors MUS T be wired to inpu ts BE FO RE they ca n be learne d An y un us ed inpu ts MUS T be jumpe red 2 Re ve rsing Ed ge an d or Ph oto Ce ll...

Page 37: ...the button to stop gate This allows gate to be moved back and fourth without leaving the operator to fine tune the open and close gate positions if desired Adjustments open and close limits CLOSED LI...

Page 38: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Page 39: ...tes LED is off B Turn knob counter clockwise to reduce sensitivity during ERD testing as needed LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or...

Page 40: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Page 41: ...NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OP...

Page 42: ...nics Box MAX BC 7 Battery Module BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER www Max US com CLOSED LIMIT OPEN LIMIT To SEC GATE input on Matrix 1 Motor MAX Megatron Toroid Box...

Page 43: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Page 44: ...econd obstruction occurred CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the STOP button on the Matrix 1 or the externally mounted Alarm Reset button to shut off the alarm and reset the gate NO...

Page 45: ...HO TOC ELL EDG E 1 EDG E 2 ID PLU G ERR OR OPE N COM CLO SE Tam per NO COM GND Tam per IN OFF OFF ON EXIT PAR TIAL OPE N OBD POR T BLA CK BOX MO TOR MO TIO N CENT ER REVE RSE SENS ITIVI TY MOT OR OVER...

Page 46: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Page 47: ...te the relay when a number of security circumstances occur making illegal entry almost impossible when the gate operator is connected to a existing building home alarm system The GATE TAMPER relay wil...

Page 48: ...O PRI_MC Fully Open Posi on Learned Fri 07 11 2014 10 58 53 INFO SEC_MC Fully Open Posi on Learned Fri 07 11 2014 10 57 40 INFO PRI_CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC P...

Page 49: ...47...

Page 50: ...48...

Page 51: ...49...

Page 52: ...99 0220 www max us com 4009963 CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Residential Commercial Brushless DC Swing Gate Operators Made in USA 14 0 0 H P 14 0 0...

Reviews: