7
3. Insert the cable lugs of battery cable flatly into the M6 battery connector of the inverter and
make sure the nuts are tightened with a torque of 2-3 Nm. Making sure polarity at both the
battery/battery isolator and the inverter is correctly connected.
WARNING: Shock Hazard
Installation must be performed with care due to high battery voltage in series.
CAUTION!!
Do not place anything between the flat part of the inverter terminal and
the ring terminal. Otherwise, overheating may occur.
CAUTION!!
Do not apply anti-oxidant substance on the terminals before
terminals are connected tightly.
CAUTION!!
Before making the final DC connection or closing DC
breaker/isolator, be sure positive (+) must be connected to positive (+) and
negative (-) must be connected to negative (-).