![maximo PV4048 HM User Manual Download Page 11](http://html.mh-extra.com/html/maximo/pv4048-hm/pv4048-hm_user-manual_1744704011.webp)
10
3. Make sure the wires are securely connected
Recommended PV module configuration
PV Module Spec.
(
reference
)
Risen Energy RSM60-6-270P
-270W
-Vmp:30.67Vdc
-Imp:8.79A
-Voc:37.88Vdc
-Isc:9.31A
Inverter Model
Q’ty of modules
Array output
4048/60A
5048/60A
3S 5P
15 Panels
4050 Watt
Voc 113.64 V
Isc 46.55 A
4048/80A
5048/80A
3S 6P
18 Panels
4860 Watt
Voc 113.64 V
Isc 55.86 A
Example: Array Voc 113.64V, coldest temperature -10°, Correction Factor 1.14,
effective Voc_max 129.5V. Use table below to find the appropriate Correction Factor
Voltage Correction Factors for Crystalline and Multi-Crystalline Silicon PV Modules