<Function 11> GS ( E pL pH fn a d1...dk (fn=11) 

ASCII           

GS    (      E    pL   p H    fn     a   d1   d k  

Hex              1D    28   45  pL   pH   0B     a   d1   dk  
Decimal       29   40    69  pL   pH   11     a    d1   dk 

  

3

(pL + pH x 256) 8  (3 pL 8,0

 pH

255) 

        fn=11,  1 a  

 4 

        48

d 57  [a=1] 

        48

d 50  [a=2] 

d=48,49     [a=3] 
d=55,56     [a=4] 
1 k 6
d1..dk= 19200

 [a=1] 

d=48[a=2] 
d=48[a=3] 
d=56[a=4]

 

 

sets the configuration item for the serial interface specified by a 
to the values specified by d1..dk 

[Format]

[

]

Range

[Default]

[Description]

MSW5-8   MSW5-7   MSW5-6   MSW5-5   MSW5-4   MSW5-3   MSW5-2   MSW5-1  Value
     48              48             48             48              48             48              48               48           0
     48              48             48             48              48             48              48               49            1
     48              48             48             48              48             48              49               48            2
     48              48             48             48              48             48              49               49            3
     48              48             48             48              48             49              48               48            4
                   
     48              49             48             49              49              48             49                48           90

a                  Configuration item 

1                  Transmission speed 

2                  Parity 

3                  Flow control 

4                  Data length 

       Example : When defining 19200 bps : 5bytes d1...dk 19200
       (Hexadecimal = 31H,39H,32H,30H,30H /Decimal= 49,57,50,48,48) 

d            Function 
48          Select no parity 

d            Function 
56          Select 8bit length

d            Function 
48          Select Flow control DTR/DSR 
              

d            Function 
48          Select no parity 
              

Flow control(a=3) is specified by d as follows:

Data Length(a=4) is specified by d as follows:

Transmission speed (a=1) is specified by number:

Parity (a=2) is specified by d as follows :

<Function 12> GS ( E pL pH fn a  (fn=12) 

ASCII      

GS   

 

  (    E    pL   pH   f n   a  

Hex         1D     28  45   pL   pH   fn   a  
Decimal  29     40  69   pL   pH   fn   a  
(pL + pH x 256) = 2  (pL=2, pH=0) 
fn=12, 1 a

Transmits the communication conditions of the serial  
interface specified by a.

[Format]

[

]

Range

[Description]

a              Communication Condition 

1              Baud rate 

2              Parity 

3              Flow control 

4             Data length 

Header                               

Flag                                 

Type of the 

Communication condition      

Separator                             

Setting value                          

NUL                                

                          37H                             55                            1 byte 

                          33H                             39                            1 byte 

                     

                     

                          1FH                             31                            1 byte 

                     30H - 39H                     48 - 57                        1 - 6 bytes 

                           00H                              0                             1 byte 

                     

                     31H - 34H                     49-52                         1 byte

                     

                     

Hexadecimal             Decimal              Amount of Data 

Configuration of the setting value 
- When the baud rate (a=1) is specified : 

Baud rate (bps)        d1         d2        d3        d4         d5         d6 

         2400                  50          52        48        48          --          -- 

         4800                  52          56        48        48          --          -- 

         9600                  57          54        48        48          --          -- 

         19200                49          57        50        48         48          -- 

         38400                51          56        52        48         48          -- 

         57600                53          55        54        48         48          -- 

         115200              49          49        53        50         48         48 

Summary of Contents for MOB-58

Page 1: ...MOB 58 Mobile Printer USER S MANUAL MANUAL REVISION EN1 0 FE ED PO WER RGE F A U H LL C POW ER M O D E E R R O R...

Page 2: ...the printer in case that splash into the printer The print head has a high temperature after work Please don t touch the print head or touch the motor shell in case scalded NOTICE Do not plug or unpl...

Page 3: ...x 2 Low noise thermal printing 3 RS 232 USB Bluetooth interfaces integrated 4 The data buffer allows the unit to receive print data even during printing 5 Bar code printing is possible by using a bar...

Page 4: ...ler for assistance 2 1 Unpacking MOB 58 Serial Cable Roll paper Recharger USB Cable USER S MANUAL USER S MANUAL s Manual er ow M P o d e l l u F E e r g r r o a r h C er ow M P o d e l l u F E e r g r...

Page 5: ...ellow BAUDRATE SETTING For example Set 9600BPS baudrate Before setting baudrate make sure the printer is on off Status 1 Press POWER button and hold on till MODE light turns blue 2 Press POWER button...

Page 6: ...SR DTR S G PRINTER SIDE HOST SIDE Pin No 1 3 2 7 8 6 5 4 Press FEED button One time Two times Three times Four times Five times Six times Seven times Signal name FG TxD RxD RTS CTS DSR SG DTR Directio...

Page 7: ...s than 5 meters is required 3 1 2 USB Connection 3 2 Connect the cables 3 2 1 Connect the AC recharger to the printer to recharge the battery NOTE To remove the DC cable connector make sure that the p...

Page 8: ...r comes off the roll 6 Pull out a small amount of paper then close the cover As picture shows Turn off the printer open the paper roll cover and clean the thermal elements of the print head with a cot...

Page 9: ...battery cabin in right position 3 press the battery till a voice from the button Chapter 6 Self test Self test checks whether the printer can perform normally or not except to functions of communicati...

Page 10: ...FEED button once to advance paper one line Press the FEED button and hold on to feed paper continuously 7 3 Tear paper After finished printing every receipt users need to tear off the receipt by thems...

Page 11: ...recharge the indicator light turns green 3 Please don t use the printer while recharging otherwise the battery s life span would be decreased Chapter 10 Specifications Printing Paper Supply Method Ch...

Page 12: ...e width print mode Cancel character Double width print selection Select character print mode Define downloaded bit image Print downloaded bit image Hexadecimal Code 0A 0C 0D 18 10 04 n 1B 0C 1B 20 n 1...

Page 13: ...status in real time n Function 1 Transmit printer status 4 Transmit paper roll sensor status 11 2 Control Commands LF FF HT Print and feed line ASCII LF Hex 0A Decimal 10 In standard mode prints the d...

Page 14: ...ESC m nL nH d1 dk ESC n Set absolute print position ESC nL nH nL nH nL nH 0 nL nH x 256 65535 0 nH 255 0 nL 255 Sets the next print starting position and the absolute print position in reference to th...

Page 15: ...the horizontal tab position ASCII Hex 1B 44 Decimal 27 68 1 Name Format Range Description Name Format Range Description Name Format Range Default Description ESC E n ESC G n ESC J n ESC L ESC M n Turn...

Page 16: ...ut put format ESC S Select standard mode ESC S Switches from page mode to standard mode Any data stored in the printer for printing in page mode is cleared ASCII Hex 1B 53 Decimal 27 83 Name Format De...

Page 17: ...ulation pitch inches Vertical start point yL yH x 256 x basic calculation pitch inches Horizontal length dxL dxH x 256 x basic calculation pitch inches Vertical length dyL dyH x 256 x basic calculatio...

Page 18: ...Decimal 28 20 This order can cancel character Double width print mode set by FS SO FS n Name Format Range 0 n 255 Description Select print modes using n as follows Select character print mode ASCII FS...

Page 19: ...n n 255 where 1 Enlargement in vertical direction 8 1 Enlargement in horizontal direction 8 n 0 Selects character size enlargement in vertical and horizontal directions ASCII GS Hex 1D 21 Decimal 29...

Page 20: ...adecimal Decimal Number of Data The following commands are enabled in the user setting mode Function 2 through Function 12 of GS E GS I Function 2 GS E pL pH fn d1 d2 d3 fn 2 Function 3 GS E pL pH fn...

Page 21: ...parity d Function 56 Select 8bit length d Function 48 Select Flow control DTR DSR d Function 48 Select no parity Flow control a 3 is specified by d as follows Data Length a 4 is specified by d as foll...