19
INSTALLATION INSTRUCTIONS
4.5 The Dimension of the Unit
Unit:mm
Capacity
12 18
-
A
B
D
E
F
G
H
C
990 660
206
505
506
907
200
203
Note:The dimension of 12000Bt u/h and
18000Btu/h are the same.
5. Floor and Standing Type
(Console)
5.1 Accessories(Console)
Ple ase check w hether the follow ing fitt ings
are of ful l scop e. If th ere ar e som e spa re
fitti ngs, p lease resto re the m care fully.
QUANTITY
SHAPE
NAME
1.Hook
7. Owner's manual
8. Installation manual
3. Remote controller
4. Frame
6. Alkaline dry batteries
(AM4)
2
1
1
2
2
1
1
5. Mounting screw
(ST2.9 10-C-H)
Installation
fittings
Remote
controller
&
Its Frame
Others
Cau tions on remote controller instal lation :
N ever throw o r bea t the c ontrol ler.
B efore install ation, opera te the remo te
co ntroll er to determ ine its location in a
re ceptio n ran ge.
K eep th e rem ote co ntroller at le ast 1m apa rt
fr om the near est TV set o r stere o equ ipmen t.
(it is necessa ry to p reven t imag e
d isturb ance s or no ise in terfer ences.)
D o not i nstall the re mote contro ller in a place
expose d to di rect sunligh t or close to a
he ating source, such as a stove .
N ote that the positive and negative p oles
ar e righ t posi tions w hen l oadin g batte ries.
Remote
controller
Remote controller
holder
Mou ntin g sc rew B
ST2 .9x1 0-C -H
SET TEMPERATURE
(
O
C)
AUTO
COOL
DRY
HE AT
FA N
HIGH
MED
LOW
TEMP.
M ODE
ON /O FF
FA N SP EE D
S WI NG
ECONOM ICT IM ER O N
RES ET LO CK
TIME R OF F
AI RDIRECTION
PO W ER FUL
Fig.43-1
5.2 Inspecting and Handling the
unit(Console)
5.3 Indoor Unit Installation(Console)
A t delivery, th e package should be
checke d and any d amage shou ld be
re porte d imm ediate ly to the se rvice agent.
W hen h andlin g the unit, take in to acc ount
th e following:
1 .
Fragil e, han dle th e unit with c are.
2 .
Keep the un it upri ght in order to
avoid compressor dama ge.
3 . Cho ose o n befo re ha nd the path along
which the unit is to be broug ht in.
4 . Move this unit a s origi nally p acka ge as
poss ible.
5 . Whe n liftin g the unit , alway s use
protectors to pre vent belt da mage and
pay attent ion to the po sition of the
unit s cent re of g ravity.
,
5.3.1 Inst allatio n pla ce
The indoor unit s hould be installed in a
location th at meets the following
requ ireme nts:
There is enoug h room for i nstallation a nd
ma intena nce.
The outlet and the in let are not impede d,
and the i nfluen ce of extern al air is the
lea st.
The air fl ow ca n reach thro ughout the
roo m.
The conn ecting pipe and d rainpipe could
be extrac ted out eas ily.
There is no direct radiation from heate rs.
(Refer to Fig.43-2 & Fig.43-3)
.
Th is man ual is subje ct to change s due to
technolo gical i mprovemen t with out
fur ther n otices .
2. Magnetic ring
(on
models)
some
1