DP-20 WEB GUIDE CONTROLLER USER MANUAL
www.maxcessintl.com
DP-20
MI 1-862 1 F
4
4-2
3.
Press the ENTER key to allow adjustment of the
System Guide Point. The current Guide Point
value will begin flashing on line 4.
4.
Use the ARROW keys to adjust the System
Guide Point to the desired position. The LCD
Panel is scaled to ±100% from the center of the
sensor bandwidth. The default range of the
Guide Point adjustment is ±80% of the sensor
bandwidth, but this range will be limited if a
Deadband above 10% is being used. ASC
settings can also limit the Guide Point range.
The
Guide
Point
change
is
effective
immediately, but not yet stored.
5.
If desired, press both of the ARROW keys
simultaneously to reset the System Guide Point
to the center of the available range, as indicated
on line 4.
6.
Press the ENTER key to store the change or
press the MANUAL key to abort the change. The
system will exit the setup menus, and return to
the Operator Level. The Guide Point value (GP)
will be displayed on Line 4 if the value is not 0.
1X.3, Measurement
1.
Press the SETUP key to enter the Setup Menus.
The GAIN menu will be displayed on the LCD
Panel.
2.
Use the ARROW keys to scroll until
MEASUREMENT is displayed on line 3.
×Ø 1C.2.1
SETUP (AUTO)
GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
×Ø 1C.2.1
SETUP (AUTO)
GUIDE POINT
-ÜÜÜÜåÜÜ+ +20.0%
1C
AUTOMATIC
×Ø -ãããããáÜÜÜÜ+
GP: +20.0%
×Ø 1C.3
SETUP (AUTO)
MEASUREMENT
×Ø 1C.1
SETUP (AUTO)
GAIN
ãÜÜÜÜÜÜÜÜÜ 10.0%
×Ø 1C.2.1
SETUP (AUTO)
GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
Summary of Contents for Fife Polaris DP-20
Page 6: ...www maxcessintl com DP 20 MI 1 862 1 F THIS PAGE INTENTIONALY LEFT BLANK...
Page 20: ...www maxcessintl com DP 20 MI 1 862 1 F THIS PAGE INTENTIONALY LEFT BLANK...
Page 57: ...www maxcessintl com DP 20 MI 1 862 1 F THIS PAGE INTENTIONALY LEFT BLANK...
Page 59: ...www maxcessintl com DP 20 MI 1 862 1 F THIS PAGE INTENTIONALY LEFT BLANK...