3–18
INSTALLATION
www.maxcessintl.com
Fife-200 Web Guiding System
MI 1-918 1 C
Power connection
Operating voltage range and current rating are listed in
Specifications (page 6-1) and shown on the label on the
controller housing.
All wiring must comply with the essential requirements of the
appropriate standard(s) and is the responsibility of the
installer.
Wiring to the Fife-200 Web Guiding System must be insulated
copper wire with a temperature rating of at least 80
⁰
C. The
wire size should be 0.82 mm^2 (18 AWG).
1.
Connect a 24 VDC +10%/-6% power supply to the power
cable. The WHITE wire is positive and the BLACK wire is
negative.
2.
Connect the PE of the building or machine to the power
cable GREEN wire.
NOTE: The negative power connection (BLACK wire) is
internally connected to the PE connection (GREEN wire). This
connection is used for EMC compliance.
WARNING – Death or injury can result from static electric
shocks.
Moving webs of material can produce large static voltage
potentials. Protect against electric shocks by installing a
conductive connection between the power cable GREEN wire
and the PE circuit of the building or machine.
CAUTION – Never place electrical cables under mechanical
strain. Always provide mechanical support of wiring with
either clamps or flexible or rigid conduit.