3–14
INSTALLATION
www.maxcessintl.com
Fife-200 Web Guiding System
MI 1-918 1 C
Controller connection
diagrams
WARNING – Death or injury can result from static electric
shocks.
Moving webs of material can produce large static voltage
potentials. Protect against electric shocks by ensuring a
conductive connection between the power cable GREEN wire
and the inside of the enclosure end plate.
-
Connect the wires from each cable to the appropriate
terminal block pins as shown in the connection diagram in
Figure 14 or Figure 15 on the following pages.
-
The power, motor, and OI cable wires are marked with the
terminal block pin numbers.
-
The sensor cable wires are not marked with the terminal
block pin numbers.
-
Each cable is marked with a part number and the cable
part number is shown in Figure 14 or Figure 15.
-
Figure 14 shows the connections for the motor and the
sensors SE-47, SE-11, SE-22, SE-44R, and SE-31.
-
Figure 15 shows the motor and sensor connections for the
SE-26A (Line Sensor).
-
When using the SE-26A (Line Sensor) only two guides can
be controlled — Guides 1 and 2.
-
Refer to drawing 220712 for a complete list of cables.