3–6
INSTALLATION
www.maxcessintl.com
Fife-200 Web Guiding System
MI 1-918 1 C
Sensor Installation
SE-47 sensor
This section only applies when using the SE-47 sensor.
1.
Mount the SE-47 amplifier in a convenient location near
the guide on a small piece of 35 mm DIN rail.
2.
Using the supplied cutting tool, trim the fiber optic cable
from the sensor head to a length needed to reach the
amplifier.
3.
Loosen the holders and position the fibers for the length
that needs to be cut.
4.
Tighten the holders to secure the fibers in the gland. Lift
the handle on the cutting tool.
5.
Insert the gland into the cutting tool as shown in Figure 4.
6.
Press down firmly on the cutting tool handle to cut off
excess length of fiber.
7.
After the fibers are cut to length, open the fiber locking
latch on the amplifier as shown by moving to position (A)
in Figure 5.
8.
Install the fibers into the fiber ports on the amplifier. Move
the fiber locking latch to position (B) to lock the fibers in
place.
1
Fiber cutting tool
1 Fiber locking latch
2
Holder
A Open
3
Gland
B Locked
Figure 4. Inserting fibers in cutting tool.
Figure 5. Installing fibers into SE-47 amplifier.
▶▶ See next page for sensor position adjustment.