CAUTION
- Ground the air conditioner.
Do not connect the ground wire to gas or water pipes, lightning rod or telephone ground wire.Incomplete grounding may
result in electric shocks.
- Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks.
- Connect the outdoor unit wires, then connect the indoor unit wires.
You are not allow to connect the air conditioner with the power source until wiring and piping the air conditioner is done.
- While following the instructions in this installation manual, install drain piping in order to ensure proper drainage
and insulate piping in order to prevent condensation.
Improper drain piping may result in water leakage and property damage.
- Install the indoor and outdoor units, power supply wiring and connecting wires at least 1 meter away from
televisions or radios in order to prevent image interference or noise.
Depending on the radio waves, a distance of 1 meter may not be sufficient enough to eliminate the noise.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
-
Don't install the air conditioner in the following locations:
■
There is petrolatum existing.
■
There is salty air surrounding (near the coast).
■
There is caustic gas (the sulfide, for example) existing in the air (near a hot spring).
■
The Volt vibrates violently (in the factories).
■
In buses or cabinets.
■
In kitchen where it is full of oil gas.
■
There is strong electromagnetic wave existing.
■
There are inflammable materials or gas.
■
There is acid or alkaline liquid evaporating.
■
Other special conditions.
8.2. Installation information
■
To install properly, please read this "installation manual" at first.
■
The air conditioner must be installed by qualified persons.
■
When installing the indoor unit or its tubing, please follow this manual as strictly as possible.
■
If the air conditioner is installed on a metal part of the building, it must be electrically insulated according to the relevant
standards to electrical appliances.
■
When all the installation work is finished, please turn on the power only after a thorough check.
■
Regret for no further announcement if there is any change of this manual caused by product improvement.
33