operating
life.
Refrigerant
R410A
is
mentioned
among
controlled
substances
and
for
this
reason
it
has
to
be
subjected
to
the
mentioned
norms.
A
particular
care
is
recommended
during
service
operations
in
order
to
reduce
as
much
as
possible
any
refrigerant
loss.
12
WHEN
THE
UNIT
GOES
OUT
OF
SERVICE
Once
the
unit
comes
to
the
end
of
its
life
cycle
and
needs
to
be
removed
or
replaced,
the
following
operations
are
recommended:
•
the
refrigerant
has
to
be
recovered
by
trained
people
and
sent
to
proper
collecting
centre;
•
compressors’
lubricating
oil
has
to
be
collected
and
sent
to
proper
collecting
centre;
•
the
frame
and
the
various
components,
if
not
serviceable
any
longer,
have
to
be
dismantled
and
divided
according
to
their
nature,
particularly
copper
and
aluminium,
which
are
present
in
conspicuous
quantity
in
the
unit.
These
operations
allow
easy
material
recover
and
recycling
process,
thus
reducing
the
environmental
impact.
13
TECHNICAL
DATA
(preliminaries)
13.1
STANDARD
VERSION
TECHNICAL
CHARACTERISTICS
Unit
Modello
N
‐
i
‐
HP
0125
0125
Circulator
integrated
0235
0235
Circulator
integrated
0250
0250
Circulator
integrated
Electric
data
Power
supply
400V/3P+N+T/50Hz
400V/3P+N+T/50Hz
400V/3P+N+T/50Hz
Maximum
power
input
kW
13,77
14,08
21,54
21,85
25,44
25,91
Maximum
starting
current
A
12,9
13,2
20,2
20,5
23,9
24,3
Maximum
current
input
A
19,9
20,3
31,1
31,6
36,8
37,4
Cooling
Cooling
capacity
(1)
kW
20,06
(22,1*)
20,1
(22,1*)
28,26
(30,2*)
28,3
(30,2*)
36,18
(38,4*)
36,1
(38,3*)
Power
input
(1)
kW
7,24
7,2
10,04
10,0
12,82
12,9
E.E.R.
(1)
W/W
2,77
2,80
2,82
2,83
2,82
2,80
Cooling
capacity
(2)
kW
27,48
(29,5*)
27,5
(29,5*)
38,40
(41,2*)
38,4
(41,2*)
48,85
(52,4*)
48,7
(52,2*)
Power
input
(2)
kW
6,72
6,7
9,70
9,7
12,65
12,8
E.E.R.
(2)
W/W
4,09
4,10
3,96
3,96
3,86
3,81
Heating
Heating
capacity
(3)
kW
21,53
(23,1*)
21,5
(23,1*)
32,43
(34,8*)
32,4
(34,8*)
41,30
(43,3*)
41,4
(43,4*)
Power
input
(3)
kW
6,43
6,4
9,63
9,6
12,30
12,4
C.O.P.
(3)
W/W
3,35
3,36
3,37
3,38
3,36
3,34
Heating
capacity
(4)
kW
25,23
(27,1*)
25,2
(27,1*)
37,91
(40,8*)
37,9
(40,8*)
48,55
(52,1*)
48,7
(52,3*)
Power
input
(4)
kW
6,13
6,1
9,21
9,2
11,75
11,9
C.O.P.
(4)
W/W
4,12
4,13
4,12
4,12
4,13
4,10
Compressor
Type
Scroll
DC
Inverter
Scroll
DC
Inverter
Scroll
DC
inverter
Number
1
2
2
Refrigerant
oil
(type,
quantity)
mL
FV50S,
2300
FV50S,
4000
total
FV50S,
4600
total
Fan
motor
Type
Motore
DC
Brushless
Motore
DC
Brushless
Motore
DC
Brushless
Number
1
1
1
Rated
power
input
kW
0.42
0.55
0.91
Rated
current
input
A
0.62
0.83
1.44
Speed
r/min
561
620
752
Rated
air
flow
m
3
/s
5.00
5.56
6.94
Refrigerant
Type
R410A
R410A
R410A
Refrigerant
quantity
kg
9.5
15.35
15.75
Design
pressure
(high/low)
MPa
4.15/2.7
4.15/2.7
4.15/2.7
Hydraulic
circuit
Water
flow
rate
(4)
L/s
1.21
1.20
1.81
1.81
2.32
2.33
Available
head
pressure
(4)
kPa
/
85.6
/
54.0
/
42.3
Internal
head
loss
(4)
kPa
32.9
49.8
61.7
Pump
rated
power
input
(4)
kW
/
0.30
/
0.31
/
0.47
Pump
max
power
input
kW
/
0.31
/
0.31
/
0.47
Pump
max
current
input
A
/
1.37
/
1.37
/
2.05
Hydraulic
connections
inch
2”F
2”F
2”F
Minimum
volume
of
water
L
75
105
150
Noise
level
Sound
pressure
(5)
dB(A)
54,4
/
SL
52,4
/
SSL
50,7
56,5
/
SL
54,7
/
SSL
53,0
59,7
/
SL
58,7
/
SSL
56,5
Dimensions
and
weight
Dimensions
(L×H×W)
mm
1198x1741x1198
1198x1741x1198
1198x1741x1198
Max.
Packing
dimensions
mm
1210x1917x1210
1210x1917x1210
1210x1917x1210
Operating
weight
kg
357
363
414
420
422
437
Net/Gross
weight
kg
349/376
355/382
406/433
412/439
414/441
428/455
Operating
conditions:
(1)
Cooling:
Outdoor
air
temperature
35°C;
inlet/outlet
water
temperature
12/7°C.
(2)
Cooling
:
Outdoor
air
temperature
35°C;
inlet/outlet
water
temperature
23/
18°C.
(3)
Heating:
Outdoor
air
temperature
7°C
DB
6°C
WB;
inlet/outlet
water
temperature
40/45°C.
(4)
Heating:
Outdoor
air
temperature
7°C
DB
6°C
WB;
inlet/outlet
temperature
30/35°C.
(5)
Sound
pressure
level
measured
at
1m
from
the
unit,
in
free
field,
according
to
ISO
3744.
Also
the
values
with
installed
accessories
SL
or
SSL
have
been
reported.
*with
Hz
Max
function
N.B.
The
performance
data
are
indicative
and
could
be
subject
to
change.
In
addition,
the
performances
declared
in
(1),
(2),
(3)
and
(4)
are
to
be
understood
referring
to
the
instantaneous
power
according
to
EN
14511.