ADVANTIX
SPA
Via
Mansoldo
Gettuglio
–
Loc.
La
Macia
Z.A.I
–
37040
ARCOLE
(Verona)
Filed
Variant
Description
CT
0,
1,
2
Heating
capacity
rating
of
the
unit.
TA
0
The
version
of
2
pipes
provides
only
Plant
Inlet
and
Outlet
Water.
1
Not
available.
2
Not
available.
IV
0
Without
vapour
injection.
1
The
vapour
injection
allows
to
increase
the
efficiency
of
the
compressor
especially
in
the
critical
conditions
(air
temp.
<7°C
or
>35°C).
CI
0
The
configuration
with
external
pump
without
management
in
parallel
includes
the
installation
of
a
piece
of
pipe
in
the
place
of
the
circulator.
N.B.:
the
external
pump
is
not
supplied.
1
The
configuration
with
integrated
circulator
provides
a
modulating
pump
with
brushless
motor,
suitable
for
the
use
of
chilled
water
and
directly
managed
by
the
controller
on
‐
board
unit.
2
The
configuration
with
external
pump
with
management
in
parallel
requests
the
installation
of
an
ON/OFF
motorized
valve
instead
of
the
circulating
pump,
in
order
to
exclude
the
unit
if
requested
by
the
management
of
multi
unit
parallel.
N.B.:
the
external
pump
is
not
supplied.
KA
0
Unit
not
equipped
with
anti
‐
freeze
kit.
1
The
antifreeze
kit
uses
a
self
‐
regulating
heating
cable
wrapped
around
the
basement
of
the
unit
near
the
condensing
coil
and
two
in
PET
heaters
placed
on
the
faces
of
the
plate
heat
exchanger.
GI
0
Unit
not
equipped
with
management
module
for
plant
1
The
additional
module
implements
some
useful
functions
for
the
plant
management,
such
as
sanitary
hot
water
SHW,
double
setpoint,
management
of
the
electric
heaters
of
the
plant,
etc.).
FAN
0
Unit
equipped
with
DC
brushless
modulating
fan
motor.
1
Not
available.
SIL
0
Unit
not
silenced.
1
The
silenced
unit
(with
SL
accessory)
provides
thermo
‐
acoustic
insulators
on
compressors.
2
The
super
silenced
unit
(with
SSL
accessory)
provides
thermo
‐
acoustic
insulators
on
compressors
and
a
special
diffuser
installed
on
the
fan
which
reduces
the
noise
livel.
TR
0
Coil
without
treatement.
1
Coil
with
only
varnishing
treatment
2
Coil
with
anti
‐
corrosion
finguard
treatment
The
CT
field
identifies
the
size
of
the
unit.
The
name
of
each
unit
provides
the
heating
capacity
anticipated
by
the
number
of
compressors.
For
example
the
unit
with
CT
=
0
(25
kW)
is
named
as
HP
‐
0125.
The
fields
TA
and
IV
identify
the
2
versions
actually
available:
‐
2
‐
pipes
without
injection
‐
2
‐
pipes
with
injection
(named
LT)
The
remaining
fields
(CI,
KA,
GI,
FAN,
SIL,
TR)
identify
the
accessories
mounted
at
the
factory,
that
should
be
requested
at
the
time
of
order.
The
variant
0
of
these
fields
identifies
the
standard
configuration
of
each
size
and
version.
Example:
the
standard
configuration
of
the
model
N
‐
i
‐
HP
‐
LT
0235
has
the
following
code:
XX10514#10100000000
.
6.1
OPTIONAL
ACCESSORIES
Hi
‐
T
Multifunction
touch
screen
remote
control
with
centralized
management
of
N
‐
i
‐
HP
and
HNS
system,
functions
of
USB
port,
temperature
and
humidity
sensors.
It
has
also
an
extremely
intuitive
interface
simplifying
the
use
of
the
controller.
CRH
Remote
control
panel
to
be
installed
in
the
room
for
the
unit
remote
controlling,
with
additional
functions
in
comparison
to
the
one
installed
on
board;
it
can
also
manage
our
hydronic
terminal
units.
N.B.:
the
fonctionality
of
the
double
setpoint
are
managed
by
mean
of
the
Hi
‐
T
controller
and
not
by
by
CRH
controller.
AG
Anti
‐
vibration
rubber
pad
to
be
installed
in
the
chassis
of
the
unit
for
possible
shock
absorption.
IMPORTANT
NOTE
ONLY
THE
OPTIONAL
ACCESSORIES
CAN
BE
REQUIRED
AFTER
THE
ORDER
OF
THE
UNIT,
WHILE
THE
FACTORY
INSTALLED
ACCESSORIES
CAN
NOT
BE
REQUIRED
AFTER
THE
ORDER
OF
THE
UNIT.