background image

17

7. AUTOMATIC ADJUSTMENT 

OF OPERATING POWER (IN-
VERTER CONTROL)

Microcomputer-based inverter control is enabled 
on this machine in order to ensure the maximum 
utilization of the discharging performance. Ad-
justment of the operating power is automatically 
continued until the pressure in the machine tank 
reaches the maximum level being set for the cur-
rently set mode. Operating sounds may change 
when the operating power is switched, but you 
do not have to worry about them. Changes in the 
sounds are not due to a failure.

The pressure level at which the output change-
over is activated varies depending on the ca-
pacity of the main power supply, type of 
extension cord used and parallel use of other 
electric equipment. If the voltage is excessively 
low, extra time will be required for the filling.

If the fill time is longer than usual or when the 
pressure does not increase, change the cur-
rent connection to the power supply (reconnect 
to the main power supply) or stop the joint use 
of the power supply with a power tool.

When capacity of the main power is 
AC 110 V (mm

2

) or less, or when it is jointly 

used with another power tool, a radical voltage 
drop results, inducing startup failure.

The circuit breaker of the power supply may be 
activated if the total current consumption re-
sulting from the parallel use with another pow-
er tool exceeds the current capacity of the 
circuit breaker.
If the circuit breaker trips, the power supply 
switch of the compressor moves to the OFF 
position.
Stop using other power tools on the same pow-
er source as the compressor or stop using an 
extension cord and connect the compressor di-
rectly to the power source. Then, after waiting 
for 30 seconds or more, turn the switch ON.

8. IN ORDER TO MAINTAIN 

PERFORMANCE

1. Drain water from the machine.

After the work is finished, turn the handle of 
the pressure-reduction valve clockwise and 
open the drain cock gradually to drain the 
compressed air and water in the air tank until 
the pressure gauge pointer of the pressure-
reduction valve points to 0. 

Not draining the water will result in the 
inside of the air tank becoming moldy, 
potentially leading to a failure.

2. (Fig.B17) The Maintenance LED lights up 

or flashes.

Operating hours of this machine are meas-
ured with a microcomputer. The MAINTE-
NANCE LED lights up as the machine 
operating hours reaches 1000 hours. If the 
Maintenance LED lights up, send the ma-
chine to your dealer or an authorized service 
facility for inspection.

3. Implement the machine inspection on a 

regular basis.

The User is requested to implement cleaning 
and inspection of the machine in order to 
maintain its performance. Please do not hes-
itate to let your dealer or authorized service 
facility inspect your machine.

4. Handle this machine carefully.

Dropping the machine inadvertently, bump-
ing it against solid objects or hitting it can 
cause deformation, cracks or damage to the 
machine. The User is advised not to invite an 
accident by dropping, bumping or hitting the 
machine.

5. Inspect the machine every time you use it.

Check and inspect the machine in conform-
ance with the procedure described in the 
SAFETY INSTRUCTIONS provided on 
page 5 and after.

6. ABOUT PRODUCTION YEAR

This product bears production number in the 
RATING LABEL. The two digits of the 
number from left indicates the production 
year.

(Example)

08826035D

Year 2008

Summary of Contents for Power Life AKHL1250E

Page 1: ...HIGH PRESSURE COMPRESSOR OPERATING AND MAINTENANCE MANUAL BEFORE USING THIS COMPRESSOR STUDY THIS MANUAL TO ENSURE SAFETY WARNING AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFE...

Page 2: ...2 Fig A Fig B...

Page 3: ...3 Fig C Fig D Fig E Fig F Fig G Fig H Fig I Fig J Fig K Fig L AC 110V AC 110V...

Page 4: ...be disconnected from the power supply RISK OF HIGH TEMPERATURES CAUTION The compressor contains some parts which might reach high temperatures RISK OF ACCIDENTAL START UP CAUTION The compressor could...

Page 5: ...ETY INSTRUCTIONS PRECAUTIONS ON USING THE COM PRESSOR IMPORTANT INFORMATION Most accidents that result from compressor op eration and maintenance are caused by the fail ure to observe basic safety rul...

Page 6: ...Clear all work ar eas of unnecessary tools debris furniture etc 9 KEEP CHILDREN AWAY Do not let visitors contact compressor extension cord All visitors should be kept safely away from work area Keep...

Page 7: ...MPRESSOR WHICH IS DEFECTIVE OR OPERATING ABNOR MALLY If the compressor appears to be operating unusually making strange noises or other wise appears defective stop using it imme diately and arrange fo...

Page 8: ...nner gasoline etc Vol atile fumes from these substances could be drawn into the compressor and compressed together with the air and this could result in an explosion 34 NEVER USE THE TOOL IN AN EXPLO...

Page 9: ...not provide adequate protection NOTE The information contained in this Instruc tion Manual is designed to assist you in the safe operation and maintenance of the compressor Some illustrations in this...

Page 10: ...emperature is 5 C to 30 C 0 C to 40 C at maximum 5 DO NOT INSTALL THE MACHINE IN A DUSTY WOODEN CHIPS ETC PLACE 6 INSTALL THE MACHINE IN THE APPRO PRIATE DIRECTION Install it appropriately 7 NEVER INS...

Page 11: ...e 2 gauges It indicates the set pressure on the pressure reduction valves H and L 24 5 bar maximum on the H side and 8 3 bar maximum on the L side 6 High pressure air chuck for MAX tools It connects t...

Page 12: ...ous operation Press the Quiet mode switch to turn on this mode A buzzer sounds with a beep and the LED lights up when the operation switching takes place The switching is available independent of whet...

Page 13: ...valve ful ly clockwise until you cannot move it anymore and make sure that the above operation moves the pressure gauge pointer Fig F at both locations As the pressure in the air tank increases due t...

Page 14: ...is machine allow you to connect MAX and the general purpose nailer or pneumatic tool Pressure reduction valve H Allows connection and use of MAX PowerLite tools of operating pressure of 24 5 bars maxi...

Page 15: ...existing in the operating environment stop using the compressor and send it to your dealer or authorized service facility for checkups or repairs 5 ABNORMALITIES DURING OPERATION If you detect any ab...

Page 16: ...top automatically LED remains lighting up with intermittent long beep sounds Pi Pi Pi until power switch is turned off Buzzer sounds Symptom Actions taken A one time short beep sound Pi At powering on...

Page 17: ...using an extension cord and connect the compressor di rectly to the power source Then after waiting for 30 seconds or more turn the switch ON 8 IN ORDER TO MAINTAIN PERFORMANCE 1 Drain water from the...

Page 18: ...ial MAX Nom du fabricant Max Co Ltd Adresse du fabricant 1848 Kawai Tamamura machi Sawagun Gunma 370 1117 Japon Proc dure d valuation de la confomit contr le interne de la production avec valuation de...

Page 19: ...in this manual will be subject to change without advance notice due to our continuous efforts to improve the quality of our products 4010263 120810 00 00 PRINTED IN JAPAN Camerastraat 19 1322 BB Almer...