background image

12

Control Panel (See Fig.B)

e

POWER LED

f

MAINTENANCE LED

If it is lit up, send the machine to your dealer or an authorized service facility for inspection. (See page 17)

g

TEMPERATURE OR ELECTRICAL PROBLEM LED

See the buzzer types in Chapter 6. (See page 16)

h

SELECTOR SWITCH

The selector switch allows switching among the following operating modes.
The factory default is 25-29 Normal mode.

Before using the control panel, remove the transparent sheet covering it on the shipped machine.

i

QUIET MODE SWITCH

This machine also offers a power-saving operation Quiet mode that you can select when you want to 
suppress the noises accompanying the operation, or when tripping of the circuit breaker is anticipated 
during continuous operation. Press the Quiet mode switch to turn on this mode.

A buzzer sounds with a beep and the LED lights up when the operation switching takes place.

The switching is available independent of whether the compressor is in operation or stopped.

Even when the circuit breaker tripped or you have disconnected the power plug from the outlet during 
operation, status of the last operation is stored in memory.

Even when the Quiet mode switch is pressed in a low temperature environment, the compressor con-
tinues running in the Normal mode until it reaches the OFF pressure. After the compressor is fully 
warmed, it shifts to the Quiet mode the next time it is used.

Operating mode

Pressure control range

Application example

ON pressure

OFF pressure

NORMAL MODE

25 bar

29 bar

Joinery work by MAX 

 tools, 

general-purpose nailers, etc.

HIGH POWER 
MODE

30 bar

34 bar

Continuous surface fastening and the 
like with MAX 

 tools.

Summary of Contents for Power Life AKHL1250E

Page 1: ...HIGH PRESSURE COMPRESSOR OPERATING AND MAINTENANCE MANUAL BEFORE USING THIS COMPRESSOR STUDY THIS MANUAL TO ENSURE SAFETY WARNING AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFE...

Page 2: ...2 Fig A Fig B...

Page 3: ...3 Fig C Fig D Fig E Fig F Fig G Fig H Fig I Fig J Fig K Fig L AC 110V AC 110V...

Page 4: ...be disconnected from the power supply RISK OF HIGH TEMPERATURES CAUTION The compressor contains some parts which might reach high temperatures RISK OF ACCIDENTAL START UP CAUTION The compressor could...

Page 5: ...ETY INSTRUCTIONS PRECAUTIONS ON USING THE COM PRESSOR IMPORTANT INFORMATION Most accidents that result from compressor op eration and maintenance are caused by the fail ure to observe basic safety rul...

Page 6: ...Clear all work ar eas of unnecessary tools debris furniture etc 9 KEEP CHILDREN AWAY Do not let visitors contact compressor extension cord All visitors should be kept safely away from work area Keep...

Page 7: ...MPRESSOR WHICH IS DEFECTIVE OR OPERATING ABNOR MALLY If the compressor appears to be operating unusually making strange noises or other wise appears defective stop using it imme diately and arrange fo...

Page 8: ...nner gasoline etc Vol atile fumes from these substances could be drawn into the compressor and compressed together with the air and this could result in an explosion 34 NEVER USE THE TOOL IN AN EXPLO...

Page 9: ...not provide adequate protection NOTE The information contained in this Instruc tion Manual is designed to assist you in the safe operation and maintenance of the compressor Some illustrations in this...

Page 10: ...emperature is 5 C to 30 C 0 C to 40 C at maximum 5 DO NOT INSTALL THE MACHINE IN A DUSTY WOODEN CHIPS ETC PLACE 6 INSTALL THE MACHINE IN THE APPRO PRIATE DIRECTION Install it appropriately 7 NEVER INS...

Page 11: ...e 2 gauges It indicates the set pressure on the pressure reduction valves H and L 24 5 bar maximum on the H side and 8 3 bar maximum on the L side 6 High pressure air chuck for MAX tools It connects t...

Page 12: ...ous operation Press the Quiet mode switch to turn on this mode A buzzer sounds with a beep and the LED lights up when the operation switching takes place The switching is available independent of whet...

Page 13: ...valve ful ly clockwise until you cannot move it anymore and make sure that the above operation moves the pressure gauge pointer Fig F at both locations As the pressure in the air tank increases due t...

Page 14: ...is machine allow you to connect MAX and the general purpose nailer or pneumatic tool Pressure reduction valve H Allows connection and use of MAX PowerLite tools of operating pressure of 24 5 bars maxi...

Page 15: ...existing in the operating environment stop using the compressor and send it to your dealer or authorized service facility for checkups or repairs 5 ABNORMALITIES DURING OPERATION If you detect any ab...

Page 16: ...top automatically LED remains lighting up with intermittent long beep sounds Pi Pi Pi until power switch is turned off Buzzer sounds Symptom Actions taken A one time short beep sound Pi At powering on...

Page 17: ...using an extension cord and connect the compressor di rectly to the power source Then after waiting for 30 seconds or more turn the switch ON 8 IN ORDER TO MAINTAIN PERFORMANCE 1 Drain water from the...

Page 18: ...ial MAX Nom du fabricant Max Co Ltd Adresse du fabricant 1848 Kawai Tamamura machi Sawagun Gunma 370 1117 Japon Proc dure d valuation de la confomit contr le interne de la production avec valuation de...

Page 19: ...in this manual will be subject to change without advance notice due to our continuous efforts to improve the quality of our products 4010263 120810 00 00 PRINTED IN JAPAN Camerastraat 19 1322 BB Almer...