background image

Page 29 of 29

Maverick Storm 4 Profile User Manual Rev. 1

Contact Us

Contact Us

Visit the applicable website above to verify our contact information and instructions to request support. 

Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record.

General Information

Technical Support

Chauvet World Headquarters

Address: 3360 Davie Rd.

Voice: (844) 393-7575

Davie, FL 33314

Fax: (954) 756-8015

Voice: (954) 577-4455

Email: 

[email protected]

Fax: (954) 929-5560

Toll Free: (800) 762-1084

Website: 

www.chauvetprofessional.com

Chauvet U.K.

Address: Unit 1C

Email: 

[email protected]

Brookhill Road Industrial Estate

Pinxton, Nottingham, UK

Website: 

www.chauvetprofessional.eu

NG16 6NT

Voice: +44 (0) 1773 511115

Fax: +44 (0) 1773 511110

Chauvet Benelux

Address: Stokstraat 18

Email: 

[email protected]

9770 Kruishoutem

Belgium

Website: 

www.chauvetprofessional.eu

Voice: +32 9 388 93 97

Chauvet France

Address: 3, Rue Ampère

91380 Chilly-Mazarin

Email: 

[email protected]

France

Website: 

www.chauvetprofessional.eu

Voice: +33 1 78 85 33 59

Chauvet Germany

Address: Bruno-Bürgel-Str. 11

28759 Bremen

Email: 

[email protected]

Germany

Website: 

www.chauvetprofessional.eu

Voice: +49 421 62 60 20

Chauvet Mexico

Address: Av. de las Partidas 34 - 3B

(Entrance by Calle 2)

Email: 

[email protected]

Zona Industrial Lerma

Website: 

www.chauvetprofessional.mx

Lerma, Edo. de México, CP 52000

Voice: +52 (728) 690-2010

Summary of Contents for Storm 4 Profile

Page 1: ...Model ID MAVERICKSTORM4PROFILE User Manual ...

Page 2: ...ent for any other purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the printer to scale the content accordingly Intended Audience Any person installing operating and or maintaining this product should completely read through the guide that shipped with ...

Page 3: ...p 6 AC Power 6 AC Plug 6 Fuse Replacement 6 Remote Device Management RDM 6 USB Software Update 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 Signal Connections 8 Control Personalities 8 DMX Linking 8 Art Net Connection 8 sACN Connection 8 Connection Diagram 8 4 Operation 9 Control Panel Description 9 Battery Powered Display 9 Home Screen 9 Control Panel Lock 9 Passcode 9 Technician Mode 9 Menu ...

Page 4: ...ay Backlight Timer 20 Loss of Data 21 Fan Mode 21 Dimmer Curve 21 Pulse Width Modulation 21 LED Power 21 Minimum Zoom Focus 21 Preset Selection 21 Preset Synchronization 22 USB Update 22 Reset Function 22 Factory Reset 22 Test Mode 22 Auto Test 22 Manual Test 22 System Information 23 Offset Mode Zero Adjust 23 Web Server 23 Gobo Wheels 24 Gobo Dimensions 24 Gobo Replacement 25 5 Maintenance 26 Pro...

Page 5: ...device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Maverick Storm 4 Profile Seetronic Powerkon IP65 power cable 2 Omega brackets with mounting hardware Quick Reference Guide Convention Meaning 1 512 ...

Page 6: ... to the surrounding environment before connecting it to power Not for permanent outdoor installation in locations with extreme environmental conditions This includes but is not limited to Exposure to a marine saline environment within 3 miles of a saltwater body of water Locations where the normal high or low temperatures exceed the temperature ranges in this manual Locations that are prone to flo...

Page 7: ...C Do not start the product at lower temperatures The minimum ambient temperature is 22 F 30 C Do not operate the product at lower temperatures In the event of a serious operation problem stop using this product immediately Expected LED Lifespan Over time use and heat will gradually reduce LED brightness Clustered LEDs produce more heat than single LEDs contributing to shorter lifespans if always u...

Page 8: ...including CMY CTO color mixing a four blade framing shutter system with rotation a color wheel 8 1 zoom two prisms five facet round and linear two rotating gobo wheels and integrated sun shield 16 bit dimming of master dimmer for smooth control of fades Variable CMY CTO color mixing system to create a wide pallet of colors CRI and CTB filters on color wheel for added flexibility Two rotating index...

Page 9: ...Profile User Manual Rev 1 Introduction Product Dimensions 10 82 in 275 mm 11 94 in 303 mm 5 04 in 128 mm 24 80 in 630 mm 17 50 in 445 mm 32 91 in 836 mm 21 10 in 536 mm 18 47 in 469 mm 12 04 in 306 mm 25 54 in 649 mm 6 18 in 157 mm ...

Page 10: ...ges to menu map options USB Software Update The Maverick Storm 4 Profile allows for software update through USB using the built in USB port The product s USB port supports up to 32GB capacity and only works with FAT32 file format To update the software using a USB flash drive do the following 1 Power on the product and plug the flash drive into the USB port 2 Once the flash drive has been detected...

Page 11: ...ting the product can support the product s weight See the Technical Specifications for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity Procedure The Maverick Storm 4 Profile comes with 2 omega...

Page 12: ...connection or a WDMX connection For more information about DMX read the DMX primer at https www chauvetprofessional com wp content uploads 2016 06 DMX_Primer pdf Art Net Connection Art Net is an Ethernet protocol that uses TCP IP that transfers a large amount of DMX512 data using an Amphenol XLRnet RJ45 connection over a large network An Art Net protocol document is available from www chauvetprofe...

Page 13: ...t the Lock Screen option 3 Select NO control panel stays unlocked or YES locks control panel Passcode After being prompted to enter the passcode enter the numbers 0920 Technician Mode The technician mode disables the pan and tilt motors allowing the output of the product to be aimed by hand To enable the technician mode of the Maverick Storm 4 Profile hold UP and LEFT while the product is powering...

Page 14: ...ACN WDMX Pan Reverse NO Normal pan YES Reversed pan Tilt Reverse NO Normal tilt YES Reversed tilt Screen Reverse NO Normal display orientation YES Inverted display orientation AUTO Automatic display orientation Pan Angle 540 540 pan range 360 360 pan range 180 180 pan range Tilt Angle 270 270 tilt range 180 180 tilt range 090 90 tilt range BL O P T Move NO Enable disable blackout while panning til...

Page 15: ...00 Hz Sets the Pulse Width Modulation frequency 1200 Hz 2000 Hz 4000 Hz 6000 Hz 15000 Hz LED POWER 64 255 Sets LED power Min Zoom Focus NO Enables disables Min Zoom Focus YES Preset Select PRESET A Recorded preset menu options PRESET B PRESET C Preset Sync NO Transfers recorded preset menu options to other Maverick Storm 4 Profile fixtures in the DMX daisy chain YES USB Update NO Update firmware v...

Page 16: ...Fine Shutter Virtual Shaking Cyan Magenta Yellow CTO Color Gobo Gobo Rotate Gobo Index Gobo2 Gobo2 Rotate Gobo2 Index Animation Animation Rotate Blade1 1 Blade1 1 Fine Blade1 2 Blade1 2 Fine Blade2 1 Blade2 1 Fine Blade2 2 Blade2 2 Fine Blade3 1 Blade3 1 Fine Blade3 2 Blade3 2 Fine Blade4 1 Blade4 1 Fine Blade4 2 Blade4 2 Fine Blade Rotate Blade Rota Fine Focus Focus Fine Focus Auto Zoom Zoom Fine...

Page 17: ...C Fixture Hours _ _ _ _ _ Shows hours product has been on LED Hours _ _ _ _ _ Shows hours LED has been on Ip _ _ _ _ _ _ _ _ Shows current IP address SubMask _ _ _ _ _ _ _ _ Shows current Subnet Mask Fan Information Base Fan1 4 Speed _ _ _ _ Shows speed of each fan in rpm _FAN_ _ _ _ x17 Speed _ _ _ _ Error Information _ _ _ _ _ Shows any errors or No Error Channel Information Frequency 000 255 Sh...

Page 18: ...Fine Blade1 2 Blade1 2 Fine Blade2 1 Blade2 1 Fine Blade2 2 Blade2 2 Fine Blade3 1 Blade3 1 Fine Blade3 2 Blade3 2 Fine Blade4 1 Blade4 1 Fine Blade4 2 Blade4 2 Fine Blade Rotate Blade Rota Fine Focus Focus Fine Focus Auto Zoom Zoom Fine Prism Prism Rotate Prism2 Prism2 Rotate Iris Frost Frost2 CMY Macro CMY Macro Speed Special Function Main Level Programming Levels Description ...

Page 19: ... Mode 55 CH is 458 Network Setup The Network Setup settings control the IP address subnet mask and universe of the product IP Mode To choose how the IP address is set 1 Go to the Network Setup main level 2 Select the IP Mode option 3 Select the desired IP mode from Manual to set a custom IP address DHCP the IP address is assigned by the connected network or Static the product uses a default preset...

Page 20: ...10 Cyan 000 255 0 100 10 11 Magenta 000 255 0 100 11 12 Yellow 000 255 0 100 12 13 CTO 000 255 0 100 13 14 Color wheel 000 007 Open 008 015 Color 1 016 023 Color 2 024 031 Color 3 032 039 Color 4 040 047 Color 5 048 059 Color 6 060 187 Color wheel indexing 188 219 Color scroll fast to slow 220 223 Stop 224 255 Reverse color scroll slow to fast 14 15 Gobo wheel 1 see Gobo Wheels 001 007 Open 008 01...

Page 21: ...low to fast 17 19 Gobo wheel 2 rotate 000 063 Gobo index 064 145 Rotation fast to slow 146 149 Stop 150 231 Reverse rotation slow to fast 232 255 Alternating clockwise counterclockwise rotation short to long 20 Gobo 2 fine rotate 000 255 Fine control 16 bit 18 21 Animation wheel 000 255 0 100 19 22 Animation wheel rotate 000 124 Rotation fast to slow 125 130 Stop 131 255 Reverse rotation slow to f...

Page 22: ...00 255 Fine control 16 bit 31 46 Prism 1 000 004 No function 005 255 Prism insert 32 47 Prism 1 rotate 000 127 Prism index 128 189 Clockwise rotation fast to slow 190 193 Stop 194 255 Counterclockwise rotation slow to fast 33 48 Prism 2 000 004 No function 005 255 Prism insert 34 49 Prism 2 rotate 000 127 Prism index 128 189 Clockwise rotation fast to slow 190 193 Stop 194 255 Counterclockwise rot...

Page 23: ...ion 064 Linear dimmer curve 065 Square dimmer curve 066 Inverse square dimmer curve 067 S curve dimmer curve 068 Linear 2 dimmer curve 069 095 No function 096 103 Pan reset 104 111 Tilt reset 112 119 Color wheel reset 120 127 Gobo wheels reset 128 135 No function 136 143 Prism reset 144 151 Blades reset 152 159 All reset 160 167 Iris reset 168 175 Frost animation wheel reset 176 183 Zoom reset 184...

Page 24: ...1 Go to the Settings main level 2 Select the Tilt Angle option 3 Select from 270 260 180 180 or 090 90 Black out on Movement To set the product to black out while the pan tilt color wheel or gobo wheels are moving 1 Go to the Settings main level 2 Select from the BL O P T Move black out on pan tilt movement BL O ColorMove black out on color wheel movement or BL O GoboMove black out on gobo wheel m...

Page 25: ...he frequency of the pulse width modulation 1 Go to the Settings main level 2 Select the PWM Option option 3 Select the frequency from 600Hz 1200Hz 2000Hz 4000Hz 6000Hz or 15000Hz LED Power To set the power of each LED color 1 Go to the Settings main level 2 Select the LED POWER option 3 Set the LED power from 64 255 Minimum Zoom Focus To enable or disable the Min Zoom Focus function 1 Go to the Se...

Page 26: ...o factory settings 1 Go to the Settings main level 2 Select the Factory Settings option 3 Select NO to cancel or YES to reset the product configuration Test Mode Auto Test To have the Maverick Storm 4 Profile automatically test all functions one after the other 1 Go to the Test main level 2 Select the Auto Test option Manual Test To manually test an individual function of the Maverick Storm 4 Prof...

Page 27: ...mware updates and the ability to change the Web Server password 1 Connect the product to power and set the Control Mode to ArtNet and the IP Mode to Static 2 Connect the product to a Windows computer with a network cable 3 On the computer set the first value of the IP address of the new network to match the first value of the IP address of the product The IP address of the product is displayed on ...

Page 28: ...heels Gobo Dimensions Gobo Wheel Gobo Description Gobo Wheel Gobo Description 1 1 Dots 2 1 Pipes Poles 2 Paperclip Party 2 Cookie Cutter 3 Orbital 3 This Way 4 Dirty Dirt 4 Fast Moves 5 Box Cutter 5 Laser Rays 6 Crazy Turns 6 Limbo Gobo Wheel 1 Gobo Wheel 2 IMAGE 30 mm 25 mm ...

Page 29: ... power outlet 2 Open the head cover by loosening the screws on the top cover 3 Separate the gobo holder away from the gobo wheel by pushing it toward the front of the moving head direction 1 in the diagram Be careful not to push the gobo out of the gobo holder 4 Extract the gobo holder by pulling it outward direction 2 in the diagram 5 On a flat surface remove the expansion ring that holds the gob...

Page 30: ...follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cotton cloth or a lens c...

Page 31: ... A 7 51 A Fuse Breaker 25 A 750 V 25 A 750 V 25 A 750 V 25 A 750 V 25 A 750 V Power I O U S Worldwide UK Europe Power Input Connector Seetronic Powerkon A Seetronic Powerkon A Power Cable Plug Bare end Bare end Type Color Quantity Power Current Lifespan LED Cool White 1 1250 W 4 A 50 000 hours Beam Angle Field Angle Cutoff Angle Zoom Angle 5 6 to 48 6 6 to 54 4 7 1 to 56 8 5 6 to 56 8 Illuminance ...

Page 32: ...ice request Clearly label the package with an RMA number Chauvet will refuse any product returned without an RMA number Before sending the product clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadeq...

Page 33: ...ookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Chauvet Benelux Address Stokstraat 18 Email BNLtech chauvetlighting eu 9770 Kruishoutem Belgium Website www chauvetprofessional eu Voice 32 9 388 93 97 Chauvet France Address 3 Rue Ampère 91380 Chilly Mazarin Email FRtech chauvetlighting fr France Website www...

Reviews: