2/3/2020
Page 66 of 78
Calder Brothers Corporation
Model: M415XT Maintainer
M415XT
Computer Diagnostic
•
Sensor damaged
Work Light Output
Error
0x807E
•
Wiring error
•
Functionality
disabled
•
Check wiring / connector
•
Sensor disconnected
•
Replace sensor
•
Sensor damaged
Blade Float Output
Error
0x807F
•
coil disconnected
•
Functionality
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Coil damaged
EP Mode Disabled
0x8080
•
Pressure sensor error
•
ePOR
disabled
•
Check wiring
•
Torque
mode disabled
•
Check pressure sensors
•
Pump
operates in ET
mode
ePOR Disabled
0x8081
•
Pressure sensor error
•
ePOR
disabled
•
Check wiring
•
Torque
mode disabled
•
Check pressure sensors
•
Pump
operates in ET
mode
CAN 1 Error
0x8082
•
CAN channel disconnected
•
BODAS
Service
disabled
•
Check wiring
•
No termination resistance
•
Add termination resistor
•
Wiring issue
CAN 2 Error
0x8083
•
CAN channel disconnected
•
Machine
functionality
disabled
•
Check wiring
•
No termination resistance
•
Add termination resistor
•
Wiring issue
CAN 3 Error
0x8084
•
CAN channel disconnected
•
Bucket
levelling
disabled
Display CAN 2
disabled
•
Check wiring
•
No termination resistance
•
Add termination resistor
•
Wiring issue
Front Speed Sensor
Error Pin 1
0x8085
•
Sensor error
•
Speed will
not be
displayed on
the display
•
Check sensor
•
Sensor damaged
•
Replace if necessary
•
Sensor disconnected
•
Check wiring
•
Wiring fault
Front Speed Sensor
Error Pin 2
0x8086
•
Sensor error
•
Speed will
not be
displayed on
the display
•
Check sensor
•
Sensor damaged
•
Replace if necessary
•
Sensor disconnected
•
Check wiring
•
Wiring fault
Front Motor HS
0x8087
•
coil disconnected
•
Check wiring / connector