2/3/2020
Page 52 of 78
Calder Brothers Corporation
Model: M415XT Maintainer
M415XT
Computer Diagnostic
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Blade Shift B Coil
Error
0x800E
•
coil disconnected
•
function
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Blade Tilt DSD Error
0x800F
•
coil currents incorrect
•
function
disabled
•
Check wiring / connector
•
coil faults
•
Replace coil(s)
•
Parameters incorrect
•
Check parameters in BODAS
Service
Blade Tilt A Coil
Error
0x8010
•
coil disconnected
•
function
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Blade Tilt B Coil
Error
0x8011
•
coil disconnected
•
function
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Check parameters in BODAS
service
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Coil damaged
•
Check coil parameters in BODAS
service
Boom A Coil Error
0x8012
•
coil disconnected
•
function
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Boom B Coil Error
0x8013
•
coil disconnected
•
Check wiring / connector
Summary of Contents for M415XT MAINTAINER
Page 2: ......