2/3/2020
Page 53 of 78
Calder Brothers Corporation
Model: M415XT Maintainer
M415XT
Computer Diagnostic
•
Wiring issues / loose connection
•
function
disabled
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Boom Control DSD
Error
0x8014
•
coil currents incorrect
•
function
disabled
•
Check wiring / connector
•
coil faults
•
Replace coil(s)
•
Paramaters incorrect
•
Check parameters in BODAS
Service
Bucket A Coil Error
0x8015
•
coil disconnected
•
function
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Bucket B Coil Error
0x8016
•
coil disconnected
•
function
disabled
•
Check wiring / connector
•
Wiring issues / loose connection
•
Replace coil
•
Current draw too high as a coil with a
different resistance is used (possible at lower
temperatures)
•
Check parameters in BODAS
service
•
Coil damaged
•
Check coil parameters in BODAS
service
Bucket Control DSD
Error
0x8017
•
coil currents incorrect
•
function
disabled
•
Check wiring / connector
•
coil faults
•
Replace coil(s)
•
Parameters incorrect
•
Check parameters in BODAS
Service
CAN Engine Rx PGN
65110 Error
0x8018
•
Error from Engine
•
No effect on
functionality
•
Check engine wire harness
•
Tank Information error
•
Data will not
be displayed
on the screen
•
Check Aftertreatment Diesel
exhaust liquid tank
•
Check tank sensor
•
Check engine ECU
0 0x8019
•
Not used
•
NA
•
NA
CAN Engine Rx PGN
57344 Error
0x801A
•
Not Used
•
NA
•
NA
CAN Engine Rx PGN
64892 Error
0x801B
•
Error from Engine
•
No effect on
functionality
•
Check wire harness