26
Setting for Brush motor with tachogenerator
In this configuration, the drive must set with the following solder bridges and below internal set-
ting:
RDT resistor calculations
To calculate RDT resistor, please use the following formula:
RDT (Kohm) = Kdt * N * 9,7
1000 * Vref
Example: Brush DC motor with the tachogenerator costant Kdt=10V/KRPM, max. speed 2500RPM
at 10V of speed reference. The result is below:
RDT (Kohm) = 10 * 2500 * 9,7
1000 * 10
Insert the commercial value resistance 18Kohm. Prefer resistance with 1% tolerance.
Note:
RDT is the value of resistor expressed in Kohm with a power rating of 1/8 or 1/4w.
Kdt is the tachogenerator costant V/KRPM.
N is the max speed express in RPM.
Vref is the max v/-VEL reference express in Volts.
Once the resistor RDT is inserted, proceed with final speed adjustment.
Operate using trimmer SPEED on the front of the drive. With Clockwise Rotation the speed increases.
With Counter Clockwise Rotation the speed decreases. The Range of regulation is about +/- 25%.
SOLDER BRIDGES
In this configuration, the drive must set with the following solder bridges and below internal setting:
Solder Bridges set for:
- Tachogenerator feedback
- Ramp time disabled
- Standard Dynamic constant
ADJUSTEMENT ZONE
Note: On the adjustement zone are not considered
here the other components used to determine other
calibrations "for example. Calibration current rating
etc.".
RDT (Kohm) = Kdt * N * 9,7
1000 * Vref
- 7,9
Example: Brush DC motor with the tachogenerator costant Kdt=10V/KRPM, max. speed 2500RPM at
10V of speed reference. The result is below:
RDT (Kohm) = 10 * 2500 * 9,7
1000 * 10
- 7,9 = 16.4 Kohm
Insert the commercial value resistance 18Kohm. Prefer resistance with 1% tolerance.
Note:
RDT
is the value of resistor expressed in Kohm with a power rating of 1/8 or 1/4w.
Kdt
is the tachogenerator costant V/KRPM
N
is the max speed express in RPM.
Vref
is the max v/-VEL reference express in Volts.
To calculate RDT resistor, please use the following formula:
Once the resistor
RDT
is inserted, proceed with final speed adjustment.
Operate using trimmer SPEED on the front of the drive. With Clockwise Rotation the speed increases.
With Counter Clockwise Rotation the speed decreases. The Range of regulation is about +/- 25%.
- 7,9
- 7,9 = 16.4 Kohm
Summary of Contents for MDCA 100
Page 1: ...1 MDCA XXX XX Precision Servodrive for DC motors...
Page 2: ...2...
Page 4: ...4 MDCA XXX XX...
Page 36: ...36 V 1 0...