- 3 -
3. Part Names and Functions
Fig. 1 shows the panel surface as it looks when the housing cover is removed.
No.
Name
Function
1
7 segment LEDs
Display the measurement results (as a percentage of the set
value).
Also display the set value for each parameter.
2
MOD button
Switches the parameter setting window.
Note: When the button is held down for three seconds or
longer, the mode will change to simulation mode.
3
STO button
Stores the data that was changed when setting parameters.
Also, when pressed while the window is being used for
measurement display, shows the level of the reflected signal.
4
button
Moves the cursor during parameter setting operations.
5
button
Changes the numeric value during parameter setting
operations.
6
POWER lamp (green) Lights up when the power supply is turned on.
7
PARAMETER
lamp
(yellow)
Lights up when a parameter setting is changed.
8
ALARM lamp
Lights up upon failure of the device.
9
Terminal block
For lead-cable connections, use pin-type crimp terminals. The
terminal layout is shown in Fig. 8.
10 Lead outlet
M 20 1.5 screw
Fig. 1 Panel Surface
Lead Outlet Side
Table 1 Part Names and Functions