background image

Customer Inquiry Sheet

 

(REK Series)

Please copy this page and above fax number after filling out form below.

A quotation

Other (                                                                                     )

An explanation of product

A demonststration

To purchase

Address:

Company:

Dept.:

Title:

Fax:

Name:

Tel:

E-mail:

Give us your requirement / comment

I would like

Please fill in below.

USA/canada

USA/canada :

 :

 +

 +

1-888-652-8651

1-888-652-8651

other countries

other countries :

 :

 

+81-6-6150-5089

+81-6-6150-5089

FAX

FAX

Warranty

We warrant that products contained in this catalog (hereinafter, the “Products”) are free from defects in material and workmanship under normal use for a period of one (1) year from the date of 
shipment thereof.  However, the warranty period for X-ray detectors and X-ray source shall be either one (1) year from the date of shipment or 1,000 hours, whichever shorter.The above warranty 
shall not apply to any Product which, at our sole judgment, has been:i)Repaired or altered by persons unauthorized by us; or ii)Connected, installed, adjusted or used otherwise than in accordance 
with the instructions furnished by us (including being used in an inappropriate installation environment, such as in corrosive gas, high temperature and humidity). We are not liable for any loss, 
damage or failure of the Products after the shipment thereof caused by external factors such as disasters.If any Product is showed to be defective as satisfactory to us, we, at our sole discretion, 
repair or replace such defective Products at no cost to the purchaser.We assume no liability to the purchaser or any third party for special, incidental, consequential, or other damages resulting 
from a breach of the foregoing warranty. This warranty excludes any and all other warranties not set forth herein, express or implied, including without limitation the implied warranties of merchant-
ability or fitness for a particular purpose. The Products are not designed and produced for such applications as requiring extremely high reliability and safety, or involving human lives (such as 
nuclear power, aerospace, social infrastructure facility, medical equipment, etc.).  The use under such environment is not covered by this warranty and may require additional design and manufac-
turing processes.

www.matsusada.com/contact

www.matsusada.com/product

For products

For contact

San Jose Office : 

2570 N.First Street Suite 200 San Jose, CA 95131

                        Tel: +1-408-273-4573   Fax: +1-408-273-4673

New York Office : 

80 Orville Drive Suite 100 Bohemia, NY 11716

                        Tel: +1-631-244-1407   Fax: +1-631-244-1496

Dallas Office : 

5430 LBJ Freeway, Suite 1200 Dallas, TX 75240

                        Tel: +1-972-663-9336   Fax: +1-972-663-9337

International Office : 

Osaka-City, Osaka Japan

                             Tel: +81-6-6150-5088   Fax: +81-6-6150-5089

Headquarters : 

745 Aoji-cho Kusatsu Shiga 525-0041 Japan

                             Tel: +81-77-561-2111   Fax: +81-77-561-2112

Boston Office : 

275 Grove Street, Suite 2-400 Newton, MA 02466

   Tel: +1-617-663-5711   Fax: +1-617-663-5331

01.099.11 24

NEW

Summary of Contents for REK Series

Page 1: ...nt Power Supply REK Series www matsusada com High power Versatile Programmable DC power supply Compact High power of 5 5kW except some models REK series NEW NEW except some models 6V to 650V 2 5A to 600A 1 6kW to 5 5kW ...

Page 2: ...cise monitoring with better recognition Operability and safety are improved with new features of key lock function and acceleration rotary encoder which accelerate the output ramp up with the speed of rotating the encoder 7kW 10kW models are also available 1 6kW to 2 5kW models 3 6kW to 5 5kW models Featuring broad output range and low noise switching configuration REK series is an ideal power sup...

Page 3: ... to 25 0 to 36 0 to 55 0 to 10 0 to 16 6 0 to 24 0 to 36 0 to 8 0 to 12 5 0 to 18 0 to 27 0 to 5 3 0 to 8 3 0 to 12 0 to 18 0 to 3 2 0 to 5 0 to 7 0 to 11 0 to 2 7 0 to 4 1 0 to 6 0 to 9 0 to 2 5 0 to 3 8 0 to 5 5 0 to 8 5 10 10 10 10 10 10 10 10 10 10 10 15 10 12 15 15 20 20 20 20 20 20 30 30 20 30 30 30 20 18 30 30 20 20 30 30 20 25 30 30 30 25 30 30 40 40 40 40 50 50 50 50 100 100 100 100 150 1...

Page 4: ...output when different setting and convenient function for production inspection process or testing which require frequent data taking Memory a Memory b Memory c 3 Set voltage and current 1 2 Press down SET Select a memory with 3 buttons NOTE It is not possible to stabilize the output by controlling back current In case of load which has inverse voltage or over rated voltage such as inductive load ...

Page 5: ...h range 1 0s to 99 9h respectively tb tc toff a b c ta t1 Note The operation accuracy of the timer when sequensing is 0 5 Be careful when you use it by the long term running operation t2 Output ON Output OFF t1 a c b ta t2 tb t3 tc t4 toff t1 and t2 can be set with range 0 to 999s respectively t1 t2 t3 and t4 can be set with range 0 to 999s respectively ta tb tc and toff can be set with range 0 0s...

Page 6: ...ogramming display Light on when voltage current remote control Output preset switch OVP OCP setting switch Keylock setting switch Exhaust hole AC input terminal M4 Not Sink Current switch 1 10 11 12 13 14 15 16 17 18 2 3 4 5 6 7 8 9 Front Panel Rear Panel nt Panel 1 1 2 3 6 5 8 9 1 0 11 12 13 14 15 4 7 Voltage Control 0 to approx 10k Current Control Blackout Protection Io Load VL Vo R S S OUTPUT 0...

Page 7: ...n Interlock Other functions Transient response time Operation temperature Storage temperature Storage humidity Dielectric voltage Accessories 50 Temp C Input Voltage V Input Voltage V Output Power kW 40 85 100 120 200 240 264 1 6 1 2 85 100 120 200 240 264 Keylock to avoid misoperation Digital master slave operation up to 250V for series operation Max 32 units for parallel or series connection Com...

Page 8: ... V COM ON when OUTPUT ON when each mode FLT OUTPUT CV CC TB1 ON when fault CV CC Delay trigger function at Master Slave control can be set for each unit Furthermore delay trigger function at Master Slave control can cancel one control functions except for Output by switching Remote Local and can set voltage and current preset Possible to change 10k to 0 for fail safe A A A RS 232C RS 485 GPIB A CO...

Page 9: ...8 35 0 18 4 5 16 85 428 16 81 427 2 36 60 17 17 436 4 M4 4 M4 3 Ø0 33 8 5 2 M6 1 38 35 0 18 4 5 16 85 428 16 81 427 2 36 60 17 17 436 Weight 8kg typ Weight 8kg typ Weight 14kg typ Weight 14kg typ 1 6kW 2 5kW Models 1 6kW 2 5kW Models 3 6kW 5 5kW Models 3 6kW 5 5kW Models O I 1 97 50 3 76 2 3 47 88 1 18 31 465 19 482 6 8 6x10 There are exhaust holes on rear panel for forced air cooling In case plac...

Page 10: ... 1 CO G32 B 32 units can be connected to 1 CO E32 32 units can be connected to 1 CO U32 In case power supply will be use following condition make sure this options selected Noisy environment such as factories ex usage of motor and coil around load or power supply Usage on high voltage floating more than 250V In case the distance between power supply and controller PC or PLC is longer than 2 meter ...

Page 11: ... is assured Important Notice F S catalog value is applied for ripple stability regulations and temperature coefficient and value if F S 1 is applied for high voltage output linearity monitor linearity and display linearity both in the range of 10 to 100 of maximum rating output Definition of specifications Connection Operation Applicable scope of specifications Please use a short lead wire that is...

Page 12: ...ed to be defective as satisfactory to us we at our sole discretion repair or replace such defective Products at no cost to the purchaser We assume no liability to the purchaser or any third party for special incidental consequential or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied includin...

Reviews: