A. Pulse Sequence
Using the stored voltage and current setting in each memory of a, b and c and
multi set function, sequence operation is possible. The setting of repetition to
say nothing of a continuous driving can be set. Various different operations,
such as repetition of memory a and b or b ,c and off, are possible by setting the
set time of memory a, b, c, and/or off to be 0.0. Thus, it makes this model
suitable for evaluation test or other applications.
B. Ramp
This function controls the ramping up and down the voltage and current to the
set value (or from set voltage and current value to 0V/0A). It is convenient to
increase(decrease) the voltage and current value slowly.
*
The Ramp sequence can be selected from [both set voltage and current], [only set voltage],
and [only set current].
C. Combination of Pulse and Ramp Sequence
Features of pulse sequence operation and ramp sequence operation can be
combined for more convenient operation. In addition, by adding multi set
function, sequence operation can be operated using stored voltage and
current settings in each memory. The setting of repetition to say nothing of a
continuous driving can be set. For example it is possible to slowly ramp up and
down the voltage and current to the three different settings, and so, it is useful
on various scenes.
ta,tb,tc and toff can be set with range
1.0s to 99.9h respectively.
tb
tc
toff
a
b
c
ta
t 1
Note The operation accuracy of the timer when sequensing is 0.5%. Be careful when you use it by the long-term running operation.
t 2
Output
ON
Output
OFF
t1
a
c
b
ta
t2
tb
t3
tc
t4 toff
t1 and t2 can be set with range 0 to 999s respectively.
t1, t2, t3 and t4 can be set with range 0 to 999s respectively.
ta, tb, tc and toff can be set with range 0.0s to 99.9h respectively.
*t1 and t2 can be set with range 0.0 to 99.9s respectively.
*t on and t off can be set with range 0 to 999s respectively.
D. Delay trigger ramp
Combination of delay trigger and ramp function.
After turning Output on, It shall start increasing ramp voltage in several
after brief space of time.
t1
t on
OUTPUT
ON
OUTPUT
OFF
t2
t off
above output control, between A to C is available.
above output control, between A to E is available.
E. Master follow
When the pulse sequence operation and the ramp work master-slave, the
output signal to the slave unit is transmitted. The slave unit can be output in
an output status different from the master unit.
* Master follow function cannot be used with –LGob, -LUs1, and –LEt option.
0V
(
Output OFF
)
Setting Voltage
/Current
0V
(
Output OFF
)
Master
Slave1
Slave2
Slave3
Pulse
sequence
setting
Ramp
setting
Delay
trigger
ramp
Pulse
sequence
setting
New useful functions
Pulse / Ramp sequence, Master follow function(-LDc option)
Pulse / Ramp sequence function(-LDe option)
In addition to standard functions, these features offer many different usage and use in wide variety of applications.