Connectors on Matrox Radient eCL boards 79
The pinout for auxiliary I/O connector B is as follows for Matrox Radient
eCL-QB.
Pin
Hardware signal
name
MIL constant
for auxiliary
signal
*
Digitizer
device
number for
auxiliary
signal
Description
1
TTL_AUX_IO_20
M_AUX_IO8
M_DEV2
TTL auxiliary signal (input/output) for acquisition path 2, which
supports: user input, user output (M_USER_BIT2 on M_DEV2), or
trigger input (trigger controller 0 on acq path 2).
2
TTL_AUX_IO_21
M_AUX_IO9
M_DEV2
TTL auxiliary signal (input/output) for acquisition path 2, which
supports: timer output (M_TIMER1 on M_DEV2), trigger input (trigger
controller 1 on acq path 2), user input, or user output (M_USER_BIT3 on
M_DEV2).
3
TTL_AUX_IO_22
M_AUX_IO2
M_DEV2/
M_DEV3
TTL auxiliary signal (input/output), shared between acquisition paths 2
and 3 for trigger input (trigger controller 2 on acq path 2; 2 on acq
path 3), user input, user output (M_USER_BIT4 on M_DEV2/M_DEV3),
and dedicated to acquisition path 2 for timer output (M_TIMER2 on
M_DEV2).
4+,5-
LVDS_AUX_IN18
M_AUX_IO10
M_DEV2
LVDS auxiliary signal (input) for acquisition path 2, which supports:
trigger input (trigger controller 0 on acq path 2), user input, or quadrature
input bit 0.
6+,8-
LVDS_AUX_IN19
M_AUX_IO11
M_DEV2
LVDS auxiliary signal (input) for acquisition path 2, which supports: user
input, trigger input (trigger controller 1 on acq path 2), timer-clock input,
or quadrature input bit 1.
7
GND
N/A
N/A
Ground.
10
GND
N/A
N/A
Ground.
12+,11- OPTO_AUX_IN17
M_AUX_IO7
M_DEV2
Opto-isolated auxiliary signal (input) for acquisition path 2, which
supports: user input or trigger input (trigger controller 1 on acq path 2).
13+,14- LVDS_AUX_OUT23 M_AUX_IO12
M_DEV2
LVDS auxiliary signal (output) for acquisition path 2, which supports:
timer output (M_TIMER1/M_TIMER2 on M_DEV2) or user output
(M_USER_BIT0 on M_DEV2).
15+,9-
OPTO_AUX_IN16
M_AUX_IO6
M_DEV2
Opto-isolated auxiliary signal (input) for acquisition path 2, which
supports: user input or trigger input (trigger controller 0 on acq path 2).
*. These MIL constants represent the signals as of MIL 10. The signals that were previously represented by M_HARDWARE_PORTn became rep-
resented by M_AUX_IOn (where the value of n remained the same between the constants). For a complete list of changes between previous MIL
versions and MIL 10, see
MILRadientCameraLinkIOConversionTable
within
MIL Release Notes
.
Summary of Contents for Radient eCL-DF
Page 6: ......
Page 18: ...18 Chapter 1 Introduction ...
Page 28: ...28 Chapter 2 Hardware installation ...
Page 60: ...60 Chapter 4 Matrox Radient eCL hardware reference ...
Page 66: ...66 Appendix A Glossary ...
Page 86: ...86 Appendix B Technical information ...
Page 95: ...Limited warranty Refer to the warranty statement that came with your product ...
Page 96: ......