Environmental specifications
Electrical specifications
• 9 V
dc
to 36 V
dc
.(0% tolerance).
Warning
To ensure EMC conformity, connect the chassis ground pin of your Matrox 4Sight
GPm unit to earth.
Matrox 4Sight GPm
Altitude
Matrox 4Sight GPm is not intended for use at altitudes exceeding
2000 m.
Operating temperature (ambient)
0 to 50°C.
Storage temperature
-40 to 85°C.
Operating humidity
10 to 90% (non-condensing).
Storage humidity
5 to 95% (non-condensing).
Matrox 4Sight GPm
Steady-state current
16 A @ 9 V to 4 A @ 36 V (144 W)
Processor consumption
17 W (Thermal design power)
Typical inrush current
1
1. These measurements were taken using one unit, under testing conditions.
V
dc
In
Transition from G3 to G2/S5
2
2. This state is also known as going from Mechanical-Off to Soft-Off.
Transition from G2/S5 to S0
3
3. This state is also known as going from Soft-Off to Full-On.
9 V
11.8 A
3.7 A
12 V
3.74 A
3.2 A
24 V
3.6 A
1.1 A
Enabled PoE consumption
+48 V
dc
, (15.40 W)