![Matrix SIMADO GFXD1111S System Manual Download Page 110](http://html1.mh-extra.com/html/matrix/simado-gfxd1111s/simado-gfxd1111s_system-manual_1740868110.webp)
104
Matrix SIMADO GFXD1111S V3 System Manual
Use following command to delete a particular concessional date table:
539-Index-#*
Where,
Index is from 01 to 16.
Use following command to delete all the entries in the Concessional date table:
539-00-#*
For FXO Port:
Program Database 2 for FXO Port.
Area Codes:
Use following command to program an area code:
511-Area Code Index-Area Code-#*
Where,
Area Code Index is from 0001 to 1000.
Area Code is a number string of maximum eight digits.
(Same Area Code logic as explained above for Mobile Port is also applicable to FXO Port)
Pulse Rates:
Use following command to program normal pulse rate for a pulse rate type:
514-Pulse Rate Type-Normal Pulse Rate-#*
Where,
Pulse Rate Type is from 01 to 25.
Normal Pulse Rate is in XXX.XX format.
Pulse rate of 180 should be programmed as 18000 whereas pulse rate of 30 should be programmed as 03000.
By default, Normal Pulse Rates are 000.00
Example:
To program the normal pulse rate as 180.00 at pulse rate type 01, issue command: 514-01-18000-#*.
Similarly, to program the normal pulse rate as 1.5 at pulse rate type 02, issue command: 514-02-00150-#*.
Use following command to program the concessional pulse rate for a pulse rate type:
515-Pulse Rate Type-Concessional Pulse Rate-#*
Where,
Pulse Rate Type is from 01 to 25.
Concessional Pulse Rate is in XXX.XX format.
Pulse rate of 180 should be programmed as 18000 whereas pulse rate of 30 should be programmed as 03000.
By default, Concessional Pulse Rates are 000.00
Example:
To program the normal pulse rate as 180.00 at pulse rate type 01, issue command: 514-01-18000-#*.
Similarly, to program the normal pulse rate as 2.5 at pulse rate type 02, issue command: 514-02-00250-#*.
Use following command to delete an entry from the pulse rate table so formed:
516-Pulse Rate Type-#*
Where,
Pulse Rate Type is from 01 to 25.
Use following command to delete all the entries from the pulse rate table:
516-00-#*
Mapping Area Codes and the Pulse Rate Types:
Use following command to program a pulse rate type for an area code:
512-Area Code Index-Pulse Rate Type-#*
Summary of Contents for SIMADO GFXD1111S
Page 1: ...SIMADO GFXD1111S System Manual...
Page 2: ......
Page 3: ...SIMADO GFXD1111S Fixed Cellular Terminal and Router with Data Port System Manual...
Page 10: ...4 Matrix SIMADO GFXD1111S V3 System Manual...
Page 24: ...18 Matrix SIMADO GFXD1111S V3 System Manual...
Page 172: ...166 Matrix SIMADO GFXD1111S V3 System Manual...
Page 187: ...Matrix SIMADO GFXD1111S V3 System Manual 181 Regulatory Information...
Page 188: ...182 Matrix SIMADO GFXD1111S V3 System Manual...
Page 189: ...Matrix SIMADO GFXD1111S V3 System Manual 183...
Page 190: ...184 Matrix SIMADO GFXD1111S V3 System Manual...
Page 193: ......