Description
This command turns ON general purpose output [num]. The standard
GPO’s on the LK202-25 output 20mA of current at 5V.
NOTE
ON means the output is pulled HIGH.
Remembered
Yes
7.4
Set Startup GPO state
Syntax
Hexadecimal
0xFE 0xC3 [Num] [state]
Decimal
254 195 [Num] [state]
Parameters
Parameter
Length
Description
Num
1
GPO number.
state
1
Startup state (0: Off, 1: On)
Description
This command will set the startup state for the GPO on the next power
up. A value of one will cause the GPO to be off on the next startup
while a value of one will cause the GPO to be on.
NOTE
This command does not affect the current state of the GPO.
Remembered
Always
8
Dallas 1-Wire
8.1
Introduction
Another convenient feature of the LK202-25 is that it provides a Dallas 1-wire interface in order to
readily communicate with up to thirty two 1-wire devices on a single bus. 1-wire communication is begun
by discovering the address of the device that you wish to communicate with. To do this you must send the
“Search for a 1-Wire Device’ command. After you have established the address of the device that you wish
to communicate with, you may begin a transaction with the device
8.2
Search for a 1-Wire Device
Syntax
Hexadecimal
0xFE 0xC8 0x2
Decimal
254 200 2