29
ERROR MESSAGE 02B5
1) CAUSE:
a. The inverter sensor is reading the normal rated current is over 10.5 amps for 60 seconds.
2) SOLUTION:
a. Use a multi - meter to check the motor cable for resistance at 3 points (Figures A, B, & C).
b. If the motor cable displays an ohm value over 4, replace the motor.
c. If the motor cable displays an ohm value under 4, replace the MCB.
8.12 02B5 ERROR TROUBLESHOOTING
FIGURE A
FIGURE B
FIGURE C
CHAPTER 8: TROUBLESHOOTING
Summary of Contents for T1X-03AC
Page 1: ...T 1 X 0 3 A C T R E A D M I L L S E R V I C E M A N U A L...
Page 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION...
Page 19: ...16 8 1 ELECTRICAL DIAGRAMS CHAPTER 8 TROUBLESHOOTING...
Page 21: ...18 8 1 ELECTRICAL DIAGRAMS CONTINUED PULSE GRIP CONNECTING WIRE N70 CHAPTER 8 TROUBLESHOOTING...
Page 75: ...72 NOTES...