21
8.4 ERROR MESSAGES ON THE CONSOLE
CLASS
LEVEL
ERROR CODE
DESCRIPTION
CONDITION
B
0140
Incline motor fail.
When the incline motor is supposed to move, it does not move.
When the error happens the incline motor will be locked. The
command "initialize" is needed to unlock the incline.
C
01A0
Incline motor disconnection.
When the incline position cable is not connected.
C
01A4
Main motor U phase
disconnection.
Main motor U phase disconnection.
C
01A5
Main motor V phase
disconnection.
Main motor V phase disconnection.
C
01A6
Main motor W phase
disconnection.
Main motor W phase disconnection.
C
01A8
Main motor over current.
Main motor over current of 7 amps.
C
01AB
Inverter Error.
Internal error of the inverter.
C
01AD
Motor over temperature.
When a heavy user makes the motor over load over go over
current.
C
02A0
Main motor failed.
The belt does not move when commanded.
C
02A1
Over AC power input voltage.
Power input voltage over range.
C
02A2
Over / low DC bus voltage.
Power input voltage over range.
C
02A8
Inverter circuit of motor drive
failed.
Motor resistance closed.
C
02AD
LCB over temperature.
LCB over temperature.
C
02B5
Inverter senses that the normal
ratedcurrentisover150%for
over 60 seconds.
Inverter sensor is reading the normal rated current is over 10.5
amps for 60 seconds.
C
02B6
Speed up has over current.
Software issue.
C
02B7
Speed down has over current.
Software Issue.
C
02B8
Running status over current.
Software Issue.
C
02B9
The inner memory IC data write
error.
MCB failure.
C
02BA
The inner memory IC data read
error.
MCB failure.
C
02BC
Ground connection or fuse error. MCB failure.
C
02BD
Inverter hardware interrupt error. MCB failure.
C
04A0
Digital communication failure.
LCB has no return message from
the UCB for 3 seconds.
Check the connection of the console cable at the UCB and MCB.
Replace the console cable, UCB, or MCB as needed.
C
04B0
No UCB response.
Check the connection of the console cable at the UCB and MCB.
Replace the console cable, UCB, or MCB as needed.
CLASS LEVEL
Class B - Will make a record in the error log. The machine will keep working.
Class C - The machine will stop and not work.
CHAPTER 8: TROUBLESHOOTING
Summary of Contents for T1X-03AC
Page 1: ...T 1 X 0 3 A C T R E A D M I L L S E R V I C E M A N U A L...
Page 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION...
Page 19: ...16 8 1 ELECTRICAL DIAGRAMS CHAPTER 8 TROUBLESHOOTING...
Page 21: ...18 8 1 ELECTRICAL DIAGRAMS CONTINUED PULSE GRIP CONNECTING WIRE N70 CHAPTER 8 TROUBLESHOOTING...
Page 75: ...72 NOTES...