background image

Operating instructions

 

eHybrid-Greaser 

MATO 

GmbH & Co. KG

 / Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120 

 

 

 

Regularly check the pressure-carrying parts (high-pressure hose) and the current-carrying parts 
for possible damage. Immediately replace any defective parts with original parts.I 

 

If non-original accessories are used, e.g. hose lines, connections, there may be a risk of 
accidents in individual cases. No liability can be accepted for accidents or damage caused by 
non-original parts. 

 

Modification or alteration to the unit is only permitted after consultation with the manufacturer. 

 

The operational safety of the unit is only guaranteed if it is used as intended. 

 

Maintenance, inspection and repair work may only be carried out by qualified personnel. 

  When changing the grease reservoir, never place the high-pressure piston pump and grease 

follower cover on a dirty surface. Dirt that gets into the lubrication system can cause damage to 
machine bearings and the high-pressure piston pump.

 

 

 

Caution: hot components cool down only gradually after being switched off. 

 

Safety-relevant parts may only be replaced or adjusted by the manufacturer.  

Intended use / warranty 

The electro-hydraulic lubricator is suitable for lubricating machines, vehicles and equipment with 
commercially available lubricants. 

 

Greases and pastes based on silicone oil and thickened with PTFE must not be processed with 

this device. Please consult with our technical department. 

 
If the operating instructions are observed and the unit is used for its intended purpose, we are 
liable within the scope of the statutory warranty obligation (see our terms of delivery).  
In case of warranty claims, please enclose the invoice from your dealer with the date of 
purchase. 

Construction and scope of delivery  

The construction including the individual components is shown on page 3. 
The hydraulic unit is supplied already assembled and ready for operation and filled with 1.25 l of 
hydraulic oil. 
The lubrication pump operates fully automatically after the gear pump is switched on. 
When the hydraulic gear pump is switched on and the trigger lever of the grease gun is 
actuated, grease delivery starts. When the trigger lever is released, the high-pressure piston 
pump automatically stops grease delivery. 

 

The scope of delivery is shown in the order confirmation. 

 

Commissioning and operation 

Remove the lid from the grease bucket. 

Press the grease follower piston onto the grease in the bucket until it is visible in the centre 
opening. The rubber lip must lie evenly against the wall of the bucket. 

Place the dust cover on the bucket with the grease follower cover and centre it with the wing 
screws. 

Slide the pumping unit holder down to the dust cover and secure with wing nut. 

Push the high-pressure piston pump through the pumping unit holder, the dust cover and the 
grease follower cover down to the grease reservoir bottom. Secure pumping unit with wing nut. 

  Before commissioning the system, check all connections for tightness and leakage 

 

Insert 220V mains plug into socket. Ensure that the hydraulic gear pump is switched off. 
As soon as the hydraulic gear pump is switched on, the high-pressure piston pump automatically 
sucks in the grease. Now actuate the grease gun until the grease comes out. Then release the 
trigger of the grease gun.  
 

The high-pressure piston pump switches off automatically after reaching the maximum operating 

pressure and is ready for use. 

10

Summary of Contents for eHybrid-Greaser 230V

Page 1: ...405 Betriebsanleitung Operating Instructions Mode d emploi Instrucciones de empleo MATO GmbH Co KG Benzstr 16 24 63165 M hlheim a Main Tel 49 0 6108 906 0 Fax 49 0 6108 906 120 Erstellt 04 2022 eHybri...

Page 2: ...Betriebsanleitung eHybrid Greaser MATO GmbH Co KG Benzstr 16 24 63165 M hlheim a Main Tel 49 0 6108 906 0 Fax 49 0 6108 906 120 2 Deutsch 3 7 English 8 12 Fran ais 13 17 Espa iol 18 22...

Page 3: ...hdruck Panzerschlauch 5 Staubschutz Deckel 6 Fettfolgekolben 7 Pumpwerkhalter 8 Hydraulik Zahnradpumpe 9 lbeh lter 10 Hydraulik Schlauchleitungen f r Hin und R ckfluss 11 Fahrwagen 10 bis 50kg 12 Lenk...

Page 4: ...gegen die geschlossene Pistole laufen lassen Beachten Sie dass sich die Zahnradpumpe und die Hochdruck Kolbenpumpe dabei erw rmt Um eine unn tige Erw rmung des Ger tes zu vermeiden die Zahnradpumpe d...

Page 5: ...Verwendung der Anlage haften wir im Rahmen der gesetzlichen Gew hrleistungspflicht sh unsere Lieferbedingungen Bei Garantieanspr chen unbedingt die Rechnung Ihres H ndlers mit Kaufdatum beif gen 3 Auf...

Page 6: ...ngabe Benennung des ET Bestellnummer Die nachfolgenden Wartungsfristen sollten unbedingt eingehalten werden um st rungsfreien Betrieb sicherzustellen Vor jedem Gebrauch j hrlich Nach Angabe Hersteller...

Page 7: ...Fettauslass R Saugrohr Durchmesser 40 mm Saugrohr L nge 495 mm 690 mm 885 mm Gewicht mobiles Ger t ohne Fettgebinde 40 kg 41 5 kg F rdermedien Schmierstoffe Es k nnen Fette bis Konsistenz 2 NLGI Klas...

Page 8: ...ure armoured hose 5 Dust cover 6 Grease follower piston 7 Pumping unit holder 8 Hydraulic gear pump 9 Oil tank 10 Hydraulic hose lines for outward and return flow 11 Trolley 10 to 50kg 12 Swivel casto...

Page 9: ...ends it must be disconnected from the mains Do not let the pump run against the closed gun for longer than 3 min Please note that the gear pump and the high pressure piston pump will heat up To avoid...

Page 10: ...tion see our terms of delivery In case of warranty claims please enclose the invoice from your dealer with the date of purchase 3 Construction and scope of delivery The construction including the indi...

Page 11: ...intenance intervals must be observed to ensure trouble free operation Before each use annually According to manufacturer High pressure grease gun X X High pressure armoured hose X X X Hydraulic hose l...

Page 12: ...tlet R Suction tube diameter 40 mm Suction pipe length 495 mm 690 mm 885 mm Weight mobile unit without grease container 40 kg 41 5 kg Pumped media lubricants Greases up to consistency 2 NLGI class 2 a...

Page 13: ...anti poussi re 6 Piston de graissage 7 Support de station de pompage 8 Pompe hydraulique engrenages 9 R servoir d huile 10 Tuyaux hydrauliques pour l aller et le retour 11 Chariot de 10 50 kg 12 Roul...

Page 14: ...e par exemple la fin de semaine de travail l appareil doit imp rativement tre d branch du r seau lectrique Ne laissez pas la pompe fonctionner contre le pistolet ferm pendant plus de 3 minutes Notez q...

Page 15: ...sage lectro hydraulique convient la lubrification de machines de v hicules et d appareils avec des lubrifiants courants Les graisses et p tes base d huile de silicone et paissies au PTFE ne doivent pa...

Page 16: ...tuyau de pression et pistolet de graissage et les pi ces sous tension de la pompe afin de d tecter tout dommage ou usure Remplacez imm diatement les pi ces d fectueuses par des pi ces d origine Comman...

Page 17: ...viron 67 dB A Filetage Sortie de graisse R Diam tre du collecteur d admission 40 mm Longueur du collecteur d admission 495 mm 690 mm 885 mm Poids appareil mobile sans r cipient graisse 40 kg 41 5 kg F...

Page 18: ...ist n de seguimiento de grasa 7 Soporte del sistema de bombeo 8 Bomba de engranajes hidr ulica 9 Recipiente de aceite 10 Tubos hidr ulicos flexibles para el flujo de ida y retorno 11 Carrito para 10 a...

Page 19: ...la boquilla cerrada Tenga en cuenta que en este caso se calientan la bomba de engranajes y la bomba de pist n de alta presi n Para evitar un calentamiento innecesario del aparato apague la bomba de en...

Page 20: ...ben utilizar grasas y pastas a base de aceite de silicona y espesadas con PTFE Si tiene dudas al respecto p ngase en contacto con nuestro departamento t cnico Si se respetan las instrucciones de uso y...

Page 21: ...dad 5 Mantenimiento y cuidados Compruebe peri dicamente que las piezas que est n bajo presi n manguera de presi n y boquilla de lubricaci n y las piezas que conduzcan corriente de la bomba no tengan d...

Page 22: ...del tubo de aspiraci n 495 mm 690 mm 885 mm Peso aparato m vil sin recipiente de grasa 40 kg 41 5 kg Sustancias bombeadas lubricantes Se pueden utilizar grasas hasta la consistencia 2 NLGI clase 2 seg...

Page 23: ...Maschinen Richtlinie 2006 42 EG EG Richtlinie EMV 2014 30 EU Angewendete harmonisierte europ ische Normen Harmonised European standards applied Suivant les normes europ ennes De acuerdo con las norma...

Page 24: ...ulations 2008 2016 No 1091 The Electromagnetic Compatibility Regulations 2016 2012 No 3032 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations...

Page 25: ...25...

Page 26: ...__________________ ____________________________ ____________________________ ____________________________ ____________________________ ____________________________ ____________________________ _______...

Page 27: ...cts Lubrication Equipment Fluid Handling Products de graissage et lubrification Equipos de lubricaci n Productos para manejo de fluidos Mat riel F rderbandverbindesysteme Gurtinstandhaltung Belt Maint...

Page 28: ...uisse T 41 0 41 4490990 F 41 0 41 4490992 info mato ch www mato ch MATO Corporation 201 Resource Drive Beckley WV 25801 West Virginia USA T 1 304 255 1280 F 1 304 255 2501 info mato usa com MATO Austr...

Reviews: