EP 100 / EP 200
EP 300 / EP 400
11
5
Maintenance and care:
The electric vane cell pump works maintenance free.
Regularly check the pressure-bearing components (pressure hose and oil filler gun) as well as
the current-carrying parts of the pump for any damage or wear. Defective parts must be
replaced immediately with genuine parts.
Ordering spare parts:
When ordering spare parts the following information is required:
Type specification, designation of the ET, order number
The following maintenance periods should be strictly observed to ensure trouble-free operation.
Before each use
Annually
According to the
manufacturer
Safety valve
X
X
Seal set
X
X
X
Pressure hose
X
X
X
Oil filler gun
X
X
Testing portable electrical
appliances. Operator
½ yearly
X
Checking for loose
connections
X
Legibility and availability of
information
X
6
Tips for fault diagnostics:
Symptom
Possible cause
Rectification
The motor is not running. Mains plug not in the socket
The wiring to the motor is faulty.
Insert mains plug into the socket.
Repair by an electrician.
Device does not
discharge any oil.
The container is empty.
Foot valve is faulty.
Check the level of the oil container.
Press reset button.
Exchange foot valve.
Device continues with
production.
Suction basket added.
Clean suction basket.