Safety information EP 100 to EP 400: 

1)

Attention! Read assembly instructions before use.

2)

Warning! Disconnect the power supply, remove the plug.

3)

Warning! Wear gloves during use.

4)

Warning! Danger from spraying oil, use safety glasses.

5)

Take note, e.g. never point pressure hose at people or animals

6)

Environmentally friendly disposal.

Failure to comply with the safety instructions may result in the endangering of people as well 
as the environment and the facility. Failure to comply with the safety instructions may lead to 
loss of any claims for damages. The operator of the facility must ensure that the contents of 
the manual, especially the safety instructions for the operators, are known. The operating 
personnel provided with suitable instruction on a regular basis. 

Instructions for EP 100 to EP 400 

-

When the facility is inactive for prolonged periods (eg time off over the weekend), the electric gear 
pump must be disconnected from the mains. Switch of pump at the on/off switch and pull out the 
plug.   

-

Do not allow the pump to run for longer than 5 min against the closed nozzle. 

-

Be aware that the pump can heat up. 

-

For the 12V - 24V design, first connect the +pole and then the -pole to the battery. 

-

The gear pump starts to operate straight away. 

-

The installation must not be operated in potentially explosive areas. 

-

Viscous media of Hazard Classes A1 and A2 can not be supported. 

-

Ensure that the 220V power socket is secured with at least 10 A. 

-

Ensure that you have a secure grip on the pump. 

-

Only use original accessories approved by MATO. In case of accidents caused by foreign parts 
liability cannot be accepted. 

-

The reliability of the system is only guaranteed when used as intended. 

-

Trace return hose back to the safety valve of the tank.   

-

Tampering or changes to the safety valve are prohibited.   

-

In combination with drum and carriage, operate parking brake when parking. 

Preparatory measures / handling 

 

Protective gloves made of leather and goggles must be worn during use. 

 

Observe safety data sheets for hazardous substances (oil, diesel) used. Instruct employees on a 
regular basis. 

 

Do not bend pressure hose sharply. 

Facility in general is only to be operated under supervision in order to prevent containers 
overflowing or the oil filler gun from slipping out. 

Summary of Contents for CMiNDTEK EP 100

Page 1: ...Betriebsanleitung Operating Instructions Mode d emploi Erstellt Änderung 76428 06 2010 01 14 EP 100 EP 200 EP 300 EP 400 ...

Page 2: ...uction tube 520 860 mm connection thread R 1 6 Angle piece with 2 barrel adapter threaded connection R 1 7 400 mm extension tube threaded connection R 1 8 On Off switch Combination possibilities with 700 l or 1000 l Tank with 200 l oil drums with without carriages barrel adapter foot valve suction basket Steel suction tube with barrel adapter foot valve suction basket Suction hose pressure hose Ho...

Page 3: ...Do not allow the pump to run for longer than 5 min against the closed nozzle Be aware that the pump can heat up For the 12V 24V design first connect the pole and then the pole to the battery The gear pump starts to operate straight away The installation must not be operated in potentially explosive areas Viscous media of Hazard Classes A1 and A2 can not be supported Ensure that the 220V power sock...

Page 4: ...osity The use of hose reels as well as the use with long conveyance stretches is not intended EP 200 EP 400 For hydraulic engine and gear oils of low to high viscosity The use of hose reels and the use with longer conveyance stretches is possible due to the high pressure performance of 16 bar Used oils may only be utilised if no solid particles are present Any other use as well as modification or ...

Page 5: ...sure trouble free operation Before each use Annually According to the manufacturer Safety valve X X Seal set X X X Pressure hose X X X Oil filler gun X X Testing portable electrical appliances Operator yearly X Checking for loose connections X Legibility and availability of information X 6 Tips for fault diagnostics Symptom Possible cause Rectification The motor is not running Mains plug not in th...

Page 6: ... cannot be supported If media not listed here is used please clarify this with our technical department If oils particularly used oils with high levels of abrasive particles metal dust sanding dust etc are pumped then a fine filter must be retrofitted in the suction line of the pump Not suitable for water chemicals and corrosive media 8 Disposal After termination of use the device is to be dispose...

Page 7: ...schinen Richtlinie 2006 42 EG EG Richtlinie EMV 2004 108 EG Angewendete harmonisierte europäische Normen Harmonised European standards applied Suivant les normes européennes De acuerdo con las normas standard europeas aplicadas DIN EN 12100 2010 DIN EN 809 1998 A1 2009 DIN EN 60204 1 2007 A1 2009 EN ISO 4413 2010 DIN EN 62079 2001 Bevollmächtigte Person für die Zusammenstellung der technischen Unt...

Reviews: