Repair / maintenance 

Before carrying out any repair or maintenance work, break off the power supply (unplug mains 
plug) and relieve pressure on the system by opening the oil filler gun. 

Regularly check the pressure-bearing components (high pressure hose) as well as the current-
carrying components for any damage. Defective parts must be replaced immediately with 
genuine parts. 

Use of non-original accessories, e.g. hose lines, connections, can in isolated cases pose the risk 
of accidents. In case of accidents or damage caused by foreign parts liability cannot be accepted. 

Modification or alteration of the device is only permitted after consultation with the manufacturer. 

The reliability of the device is only guaranteed when used as intended. 

Maintenance, inspection and repair work must only be performed by qualified personnel. 

Caution:

 hot components only cool gradually after being shut down. 

Safety-related parts (e.g. safety valve) may only be replaced or adjusted by the manufacturer.  

Intended use / guarantee 

The electric gear pump is suitable for decanting and filling of oil. The bypass valve integrated in 
the pump body is at the limit of the max. delivery pressure of the pump. 

EP 100, EP 300

 

230 V AC  

For hydraulic and motor oil  
of low to medium viscosity. 
The use of hose reels as well as the use with 
long conveyance stretches is not intended.  

EP 200, EP 400, 

 

For hydraulic, engine and gear oils  
of low to high viscosity. 
The use of hose reels and the use with longer 
conveyance stretches is possible due to the high 
pressure performance of 16 bar. 

Used oils may only be utilised if no solid particles are present. Any other use as well as 
modification or alteration of the installation is only permitted after consultation with the 
manufacturer. 

If the installation is used as intended and in accordance with the instructions, we are liable under 
the statutory warranty (see our Terms and Conditions).  
The invoice from your dealer with the date of purchase must be enclosed with warranty claims 

Assembly and delivery 

The structure, including the individual components, is depicted on page 3. 

Set up and operation of EP 100 to EP 400 

-

Screw telescopic suction tube (5) into angle piece (6). 

-

Screw telescopic suction tube with elbow in the R 2" connection of the tank. 

-

Set gear pump (1) onto the tank. When using the pump holder for the 700/1000 litre tank, the 
carrying handle of the pump can be removed. 

-

Trace return hose back to the safety valve of the tank. 

-

Connect suction hose (2) to the pump (1) and the angle piece (6). 

-

Assemble oil filler gun (4) and pressure hose (3) at the pressure side of the pump. 
Check all connections for a firm fit and leaks before starting the system.

-

Insert 220V mains plug into the socket. Check that the pump is switched off.

Summary of Contents for CMiNDTEK EP 100

Page 1: ...Betriebsanleitung Operating Instructions Mode d emploi Erstellt Änderung 76428 06 2010 01 14 EP 100 EP 200 EP 300 EP 400 ...

Page 2: ...uction tube 520 860 mm connection thread R 1 6 Angle piece with 2 barrel adapter threaded connection R 1 7 400 mm extension tube threaded connection R 1 8 On Off switch Combination possibilities with 700 l or 1000 l Tank with 200 l oil drums with without carriages barrel adapter foot valve suction basket Steel suction tube with barrel adapter foot valve suction basket Suction hose pressure hose Ho...

Page 3: ...Do not allow the pump to run for longer than 5 min against the closed nozzle Be aware that the pump can heat up For the 12V 24V design first connect the pole and then the pole to the battery The gear pump starts to operate straight away The installation must not be operated in potentially explosive areas Viscous media of Hazard Classes A1 and A2 can not be supported Ensure that the 220V power sock...

Page 4: ...osity The use of hose reels as well as the use with long conveyance stretches is not intended EP 200 EP 400 For hydraulic engine and gear oils of low to high viscosity The use of hose reels and the use with longer conveyance stretches is possible due to the high pressure performance of 16 bar Used oils may only be utilised if no solid particles are present Any other use as well as modification or ...

Page 5: ...sure trouble free operation Before each use Annually According to the manufacturer Safety valve X X Seal set X X X Pressure hose X X X Oil filler gun X X Testing portable electrical appliances Operator yearly X Checking for loose connections X Legibility and availability of information X 6 Tips for fault diagnostics Symptom Possible cause Rectification The motor is not running Mains plug not in th...

Page 6: ... cannot be supported If media not listed here is used please clarify this with our technical department If oils particularly used oils with high levels of abrasive particles metal dust sanding dust etc are pumped then a fine filter must be retrofitted in the suction line of the pump Not suitable for water chemicals and corrosive media 8 Disposal After termination of use the device is to be dispose...

Page 7: ...schinen Richtlinie 2006 42 EG EG Richtlinie EMV 2004 108 EG Angewendete harmonisierte europäische Normen Harmonised European standards applied Suivant les normes européennes De acuerdo con las normas standard europeas aplicadas DIN EN 12100 2010 DIN EN 809 1998 A1 2009 DIN EN 60204 1 2007 A1 2009 EN ISO 4413 2010 DIN EN 62079 2001 Bevollmächtigte Person für die Zusammenstellung der technischen Unt...

Reviews: