Matelec FPC-30010 Owner'S Manual Download Page 8

MANUFACTURED BY MATelec AUSTRALIA                  EMAIL:  [email protected]

MATelec reserves the right to alter technical specifications without notice

A  quick  reference  to  the  controller’s 
Keypad  and  Indicator  functions  and 

meanings.

KEYPAD

INDICATORS

PUSH BUTTONS

POWER ON

Power is turned on

ON STEADY

A  high  level  alarm  has  been 
present for the preset time

FLASHING

A low level alarm is present

ON STEADY

A  pump  fault/overload  has 

occured

FLASHING

A prime loss fault has occured

The pump is set to Automatic 

Pumping Mode

The  pump  is  set  to  Manual 

Pumping Mode

To turn pump off

DISTRIBUTED BY:

8

INSTALLATION  DATE:

SERIAL NUMBER:

Dual Pump

Controller

PUMP 1

PUMP 2

AUTO

OFF

AUTO

OFF

MAN

MAN

MUTE/

RESET

PUMP ON

PUMP ON
FAULT

FAULT

LEVEL

ALARM

POWER

ON

DANGER - HIGH VOLTAGE

DO NOT REMOVE COVER.  AUTHORIZED PERSONS ONLY

Steady - Overload

Flash - Prime Loss

Steady - Overload

Flash - Prime Loss

Press and hold

for 3 secs to reset 

Steady - High Level

Flash - Low Level

MUTE/

RESET

AUTO

OFF

MAN

RUNNING

FAULT

ON STEADY

Pump is switched on to run

MOMENTARY PRESS

To mute audible buzzer

PRESS FOR 3 SECS

To reset alarms and faults

PRESS CONTINUOUS

To test indicator lights, strobe 

and siren

POWER

ON

HIGH

LEVEL

Summary of Contents for FPC-30010

Page 1: ...AUTO OFF AUTO OFF MAN MAN MUTE RESET PUMP ON PUMP ON FAULT FAULT LEVEL ALARM POWER ON DANGER HIGH VOLTAGE DO NOT REMOVE COVER AUTHORIZED PERSONS ONLY Steady Overload Flash Prime Loss Steady Overload...

Page 2: ...Features WARNING All electrical connections must be carried out by a suitably qualified and registered electrician Prior to Installation ensure power supply is isolated Power supply must be Circuit Br...

Page 3: ...oller PUMP 1 PUMP 2 AUTO OFF AUTO OFF MAN MAN MUTE RESET PUMP ON PUMP ON FAULT FAULT LEVEL ALARM POWER ON DANGER HIGH VOLTAGE DO NOT REMOVE COVER AUTHORIZED PERSONS ONLY Steady Overload Flash Prime Lo...

Page 4: ...el Standard configuration plus low level Start Stop High level and Low level Standard configuration plus Prime Loss enabled on Low level Input 1 Pressure Pumping configuration Lead Lag and Low pressur...

Page 5: ...d Note that after a high level is triggered the pumps will both run until the pump Start and Stop inputs are opened Typical operation for Mode D Low pressure switch set at say 200kPa Lag pump pressure...

Page 6: ...roller press and hold the Mute Reset button on the keypad continuously for a period of 3 seconds until an acknowledgement beep is heard Pump Fault A Pump Fault is indicated for two types of Faults A T...

Page 7: ...LE PUMP 1 ISOLATOR 20amp 2 POLE PUMP 2 ISOLATOR CONTACTOR 2 PUMP 2 DATA OUTPUT 2amp CONTROL CIRCUIT BREAKER ISOLATOR SWITCH STROBE BUZZER TRANSFORMER 12Vac 12Vdc 240Vac INPUT 1 SWITCH INPUT 2 SWITCH I...

Page 8: ...to Automatic Pumping Mode The pump is set to Manual Pumping Mode To turn pump off DISTRIBUTED BY 8 INSTALLATION DATE SERIAL NUMBER Dual Pump Controller PUMP 1 PUMP 2 AUTO OFF AUTO OFF MAN MAN MUTE RE...

Reviews: