Page of 45
1812367-12
9
INSTALLATION
Electrical Shock
High voltage danger from power source! Consult a qualified electrician for proper
installation of receptacle. This welder must be grounded while in use to protect the
operator from electrical shock.
Do not remove grounding prong or alter the plug in any way. Use only the supplied
adapter between the plasma cutter's power cord and the power source receptacle. Make
sure the POWER switch is OFF when connecting your welder’s power cord directly to a
properly grounded 230 VAC, 60 HZ, Single Phase, 50 Amp input power supply. Or, when
using the supplied 120V adapter, connect the 120V Adapter to a properly grounded 120V,
20 Amp input power supply.
1. POWER REQUIREMENT 230V - AC single phase 230V (220-240V) 50/60 HZ fused with a 50
amp time delayed fuse or circuit breaker is required. DO NOT OPERATE THIS UNIT if the
ACTUAL power source voltage is less than 215 volts AC or greater than 240 volts AC.
2. POWER REQUIREMENT 120V - AC single phase 120V (110-130V) 50/60 HZ fused with a 20
amp time delayed fuse or circuit breaker is required. DO NOT OPERATE THIS UNIT if the
ACTUAL power source voltage is less than 110 volts AC or greater than 130 volts AC.
a. When connecting this unit to 120V power, connect the 120V adapter cord to the power
cord pigtail that is attached to the machine.
3. EXTENSION CORD - We do not recommend an extension cord because of the voltage drop
produced. This drop in voltage can affect the performance of the welder. If you need to use an
extension cord, check with a qualified electrician and your local electrical codes for your specific
area.
4. INSTALL THE WIRE ROLLER - The wire roller has been factory installed. However, check to
make certain the correct wire groove is in place to accommodate the size of wire you are using.
Open the wire feed compartment. Adjust the drive roller according to the following steps. See
Figure 2 about the wire feeder structure:
Figure 2
1
3
2