008-03 - Gas cooker
6
Primary air distance "A"
Natural gas G20
LP gas G30/G31
8
1
8
3
TABLE 1
Model
Category
Construction type
Air necessary for combustion
Nominal capacity
Minimum capacity
Overall capacity (Gas)
Input pressure
Natural gas 2H
LP gas 3+
Gas connection values (consumption)
Natural gas 2H
LP gas 3+
Nozzles Ø 1/100 mm.
Main
burner
G20
G30/G31
(HuB = 9.45 kWh/m
3
) in m
3
/h
(HuB = 12.87 kWh/kg) in kg/h
Nominal capacity
Low flame
Nominal capacity
Low flame
G20
G30/31
20 mbar
28/37 mbar
ABJ00001
ABJ00002
ABA20004
ABA20002
II2H3+
A
m
3
/h
kW
kW
B
Ø 70
5
2.5
0.7
C
Ø 90
7
3.5
0.7
0.265
0.196
0.370
0.274
6.0
12.0
12.0
18.0
12.0
kW
kW
kW
kW
kW
0,63
1,27
1,27
1,90
1,27
-
-
-
-
-
0,47
0,94
0,94
1,41
0,94
hour consumption
G20
m
3
/h
G25
m
3
/h
G30/G31
kg/h
120
adjustable
80
40
145
adjustable
95
40
N. nozzles pilot burner
G20
G30/G31
-
-
-
-
Electrotechnical data
Power electric oven :
60 GN 1/1 -
2.56
kW
90 GN 1/1 -
2.56
kW
Voltage rating:
AC 230 50 Hz
Lead wire / Section
3 x 1.5 mm2