39
CE Regulation use and maintenance manual
IT IS FORBIDDEN TO EVEN PARTIALLY REPRODUCE THE TEXT AND/OR ILLUSTRATIONS.
www.masterweld.co.uk
TABLE 3
ELECTRICAL
APPLIANCE
CATEGORY
GAS GROUPS
I
Mines (methane)
II
Non-mines
Category II is divided into:
D
A
N
G
E
R
IIA
Propane
IIB
Ethylene
IIC
Hydrogen, acetylene
TABLE 4
TEMPERATURE
CLASS
IGNITION
TEMPERATURE
[°C]
MAX. TEMPERATURE
ACCEPTED ON THE
APPLIANCE [°C]
T1
>450
450
T2
>300<450
300
T3
>200<350
200
T4
>135<200
135
T5
>100<135
100
T6
>85<100
85
Table 5 and 6 refer to the specific protection categories of the appliances and electric
components.
TABLE 5
TYPE
CATEGORY
EN
GROUP
GENERAL RULES
50014
IMMERSION IN OIL
o
50015
M2-2
INTERNAL OVER-PRESSURE
p
50016
M2-2
POWDER FILLING
q
50017
M2-2
EXPLOSION-PROOF CASING
d
50018
M2-2
INCREASED SAFETY
e
50019
M2-2
INTRINSICALLY SAFE
ia
50020
M1-1
SPARK PROTECTION “N”
n
50021
3
ENCAPSULATION
m
50028
M2-2
CATEGORY 1G
50284
1
CATEGORY 1M
50303
M1
APPLIANCE CATEGORY
CATEGORY 1
CATEGORY 2
CATEGORY 3
Minimum protection
Non-applicable
IP 6X
IP 5X
Table 7 refers to the minimum reference temperatures (T reference) for ignition of the dusts.
TYPE OF DUST
IGNITION TEMPERATURE
°C
MAX.TEMPERATURE OF
THE APPLIANCE °C
DUST CLOUD
2/3 x T
CL
≤ 2/3 x T
CL
LAYER< 5 mm
T
5mm
- 75 °C
≤ (T
5mm
- 75 °C)
LAYER> 5 mm
Depends on the thickness
T
5mm
Where:
• T
CL
= Dust ignition temperature
• T
5mm
= Ignition temperature of a 5mm layer of dust
• T
Riferimento
= The lower between T
nube
and T
strato