MAC-PLUS
33
Value
Meaning
Factory setting
Adjustable range
Output alarm
High alarm on
High output voltage alarm on
15.25 / 30.50 V
8-16 / 16-32 V
High alarm off
High output voltage alarm off
14.75 / 29.50 V
8-16 / 16-32 V
Low alarm off
High output voltage alarm off
11.00 / 22.00 V
8-16 / 16-32 V
Low alarm on
High output voltage alarm on
10.00 / 20.00 V
8-16 / 16-32 V
Low alarm delay
Low output alarm delay time
30 s
0-300 s
DIP switch
12345678
DIP switch state 0=off, 1=on
0
0,1
Event source
(available in upcoming
software update)
Description
Off
Device state is Off
Standby
Device state is Standby
Charging
Device state is Charging
Error
Device state is Error
Bulk
State of charge is Bulk
Absorption
State of charge is Absorption
Float
State of charge is Float
Any alarm
Any of the alarms is triggered
Event command
Description
Standby
Command to switch on/off the Mac Plus. If the Mac Plus was switched off
by means of this event command, it will switch on again when it come out
of sleep mode.
Bulk
(available in upcoming
software update)
Command to start the Bulk state of charge
Absorption
(available in upcoming
software update)
Command to start the Absorption state of charge
Float
(available in upcoming
software update)
Command to start the Float state of charge
Summary of Contents for Mac Plus 12/24-30
Page 2: ...2 MAC PLUS ...
Page 8: ...8 MAC PLUS 4 Dimensions 146 mm 198 mm 255 mm 66 mm 165 mm ...
Page 10: ...10 MAC PLUS 6 Identification label Identification label ...
Page 13: ...MAC PLUS 13 Installation drawing A Installation drawing B ...
Page 28: ...28 MAC PLUS Do not make ring networks Do not make T connections in the network ...
Page 34: ...34 MAC PLUS ...
Page 35: ...MAC PLUS 35 ...