MAC-PLUS
29
15. MasterBus: Control and Configuring of the Mac Plus
Monitoring
Value
Meaning
Default
Adjustable range
Status
Device state
Shows the actual operation mode:
Standby / Charging / Alarm / Off
(read only)
Charge state
State of charge algorithm: Off / Bulk /
Absorption / Float / Constant voltage
(read only)
Standby
Button to toggle the device state.
Note: in the standby mode, the Mac Plus
can be switched on again automatically.
This happens, for example, after a restart.
On
On, Off
General
Input voltage
Voltage at the input
(read only)
Input current
Current of the input
(read only)
Output voltage
Voltage at the output
(read only)
Output current
Current of the output
(read only)
Bat. volt sense
Battery voltage measured by the battery
voltage sensor
. If the Shunt device function
is enabled for a MasterShunt (MSH) or a
MLI-Ultra (BAT): voltage measured by the
MasterShunt / MLI-Ultra.
(read only)
Remote sw.
input
Remote input signal detected. Only
applicable when Remote input mode is
active low or active high configured.
(read only)
Temperatures
Device
Device temperature
(read only)
Battery
Actual battery temperature measured by the
Battery temperature sensor.
If no battery temperature sensor is used or
when Battery is set to “Li-Ion”: “---“ is
shown.
If the Shunt device function is enabled for a
MasterShunt (MSH): Battery temperature
measured by the MasterShunt is shown
(available in upcoming software update).
(read only)
Summary of Contents for Mac Plus 12/24-30
Page 2: ...2 MAC PLUS ...
Page 8: ...8 MAC PLUS 4 Dimensions 146 mm 198 mm 255 mm 66 mm 165 mm ...
Page 10: ...10 MAC PLUS 6 Identification label Identification label ...
Page 13: ...MAC PLUS 13 Installation drawing A Installation drawing B ...
Page 28: ...28 MAC PLUS Do not make ring networks Do not make T connections in the network ...
Page 34: ...34 MAC PLUS ...
Page 35: ...MAC PLUS 35 ...