MAC-PLUS
25
NiCad
Bulk voltage
14.50/29.00 V
Max bulk time
480 min
Min bulk time
120 s
Start bulk time
13.25/26.50 V
Bulk ret. volt.
13.50/27.00 V
Bulk return time
30 s
Abs. voltage
14.50/29.00 V
Max absorp. time
240 min
Min absorp. time
240 min
Return amps
6.0 %*I max
Float voltage
14,50/29.00 V
14. MasterBus
What is MasterBus
All devices that are suitable for MasterBus are marked by the MasterBus symbol
MasterBus is a fully decentralized data network for communication between the different Mastervolt
system devices. It is a CAN-bus based communication network which has proven itself as a reliable
bus-system in automotive applications. MasterBus is used as power management system for all
connected devices, such as the inverter, battery charger, generator and many more. This gives the
possibility for communication between the connected devices, for instance to start the generator
when the batteries are low.
MasterBus reduces complexity of electrical systems by using UTP patch cables. All system
components are simply chained together. Therefore each device is equipped with two MasterBus
data ports. When two or more devices are connected to each other through these data ports, they
form a local data network, called the MasterBus. The results are a reduction of material costs as
only a few electrical cables are needed and less installation time.
For central monitoring and control of the connected devices Mastervolt offers a wide range of panels
which show full status information of your electrical system at a glance and a push of a button. Four
different panels are available, from the small Mastervision compatible 120 x 65 mm LCD screen up
to the full colour EasyView 5. All panels can be used for monitoring, control and configuration of all
connected MasterBus equipment.
Summary of Contents for Mac Plus 12/24-30
Page 2: ...2 MAC PLUS ...
Page 8: ...8 MAC PLUS 4 Dimensions 146 mm 198 mm 255 mm 66 mm 165 mm ...
Page 10: ...10 MAC PLUS 6 Identification label Identification label ...
Page 13: ...MAC PLUS 13 Installation drawing A Installation drawing B ...
Page 28: ...28 MAC PLUS Do not make ring networks Do not make T connections in the network ...
Page 34: ...34 MAC PLUS ...
Page 35: ...MAC PLUS 35 ...