32
MAC-PLUS
MasterShunt (MSH) or a MLI-
Ultra battery (BAT). Enabling
this function allows
to: - Compensate the charge
voltage for cable losses - Adjust
the actual Charge state based
on the state of charge of the
battery - Compensate the
charge voltage for deviating
battery temperatures
(MasterShunt only)
BAT+Product
Name
Bulk
Bulk voltage
Bulk voltage
14.25 / 28.50 V
8-15 / 16-30 V
Max. bulk time
Maximum bulk time
480 min
0-1440 min
Min. bulk time
Minimum bulk time
120 s
0-240 s
Start bulk time
Start bulk timer
13.25 V
8-15 / 16-30 V
Bulk ret. volt
Return to bulk voltage
12.80 / 25.60 V
8-15 / 16-30 V
Bulk return time
Return to bulk time delay
30 s
0-240 s
Absorption
Abs. voltage
Absorption voltage
14.25 / 28.50 V
8-15 / 16-30 V
Max absorp. time
Maximum absorption time
240 min
0-1440 min
Min absorp. time
Minimum absorption time
15 min
0-240 min
Return amps
Return amps (% of maximum
charge current)
6 %
0-50 %
Float
Float voltage
Float voltage
13.25 / 26,50 V
8-15 / 16-30 V
Constant voltage
Constant voltage
Constant output voltage
13.25 / 26.50 V
8-15 / 16-30 V
Input alarm
High alarm on
High input voltage alarm on
16.00 / 32.00 V
8-16 / 16-32 V
High alarm off
High input voltage alarm off
15.50 / 31.00 V
8-16 / 16-32 V
Low alarm off
Low input voltage alarm off
11.00 / 22.00 V
8-16 / 16-32 V
Low alarm on
Low input voltage alarm on
10.00 / 20.00 V
8-16 / 16-32 V
Low alarm delay
Low input alarm delay time
5 s
0-300 s
Summary of Contents for Mac Plus 12/24-30
Page 2: ...2 MAC PLUS ...
Page 8: ...8 MAC PLUS 4 Dimensions 146 mm 198 mm 255 mm 66 mm 165 mm ...
Page 10: ...10 MAC PLUS 6 Identification label Identification label ...
Page 13: ...MAC PLUS 13 Installation drawing A Installation drawing B ...
Page 28: ...28 MAC PLUS Do not make ring networks Do not make T connections in the network ...
Page 34: ...34 MAC PLUS ...
Page 35: ...MAC PLUS 35 ...