Mastervolt EasyView 5 Manual Download Page 23

EasyView 5 - User and Installation Manual  

 

23

 

 

 

 

 

Event X 
Command 

Event-based command

  

Action to be taken by the Event X target.  
The "Power save" command can be used 
to set the EasyView 5 in standby mode. 

Disabled 

Disabled, State,  
Lock, 
Feedback 1-6, 
Buzzer, 

Power save, 

Message 1-6 

 

Event X Data  Event 1 data controls the Event X 

command, see section 6.8 for explanation. 

Off 

Off, On, Copy, 
Copy Invert, 
Toggle  

 

6.8 

Event data 

The figure on the right shows an example of Input 

(pulses) and Output (data) to explain the Event 

Data.  
On changes the status to On at the first signal.  
Off changes the status to Off at the first signal.  
Copy lets the status follow the input.  
Copy Invert lets the status follow the opposite of 

the input. Copy is used for dimming too by holding 

the pulse switch pressed for a longer time.  
Toggle changes the status at the first signal and 

back at the second signal. It is used in 

combination with a pulse switch.  

 

Event Data 

6.9 

Configuring other devices 

Monitoring and configuring other devices is possible by selecting a device in the EasyView 5 device 

list, see section 6.2. Refer to the user manual of the connected device for an overview of all 

available settings. Settings are stored in the memory of the selected device. This means that 

switching off or disconnecting of the EasyView 5 will not affect the settings of the connected 

devices. See section 6.6 to enable configuration of all connected devices. 

Summary of Contents for EasyView 5

Page 1: ...n anderen Sprachen herunterzuladen besuchen Sie bitte unsere Website Pour t l charger ce manuel dans d autres langues consultez notre site Web Para descargar este manual en otros idiomas visite nuestr...

Page 2: ...12 5 2 1 Switching on off or standby 12 5 2 2 Locking 12 5 2 3 Home 12 5 3 Dashboard and navigation 13 5 4 Maintenance 13 6 Monitoring and configuration 14 6 1 Favorite pages 14 6 1 1 Adding widgets t...

Page 3: ...gure and operate all connected devices in a MasterBus network 1 1 Parts Parts 1 Front cover 2 Display panel 3 Top cover 4 Seal 5 Wall box 6 Bottom cover Always use the front cover when the EasyView 5...

Page 4: ...4 EasyView 5 User and Installation Manual 1 2 Connections Connections 1 MasterBus port 1 2 MasterBus port 2 3 USB device port 4 Power input 12 24 V...

Page 5: ...d Installation Manual 5 1 3 Accessories Accessories 1 Mastervolt EasyView 5 2 MasterBus cable 6 meter 20ft 3 MasterBus terminator 4 12 24 V connector 5 Mounting screw 4 pcs 4x30mm PH2 6 Mounting screw...

Page 6: ...nder performance damage or failure of the product and may void this warranty The warranty is limited to the cost of repair and or replacement of the product Costs for labor or shipping are not covered...

Page 7: ...Every device that is compatible with MasterBus is equipped with two data ports The devices are simply chained together forming a local data network Monitoring panels such as the EasyView 5 can be use...

Page 8: ...evices can be connected together MasterBus needs a terminating device on both ends of the network The electric power for the network comes from the connected devices At least one device in the network...

Page 9: ...ions The EasyView 5 offers three mounting options Panel mounting onto the wall box see section 4 1 Flush mounting in an 82 x 113 mm hole see separate instruction sheet with saw template Clamp mounting...

Page 10: ...the mounting hole are too big the wall box can also be used as a mounting clamp Position the wall box at the back side of the installation panel and use the supplied screws to fasten the display onto...

Page 11: ...see section 1 3 4 3 1 Aux power connector Connect the positive wire to the left terminal the negative wire to the right terminal of the connector Use a 3mm flat blade screw driver to tighten the scre...

Page 12: ...long press i e press and hold the button for about 3 seconds the Home button and tap the Off option in the menu that appears To switch to standby mode long press the Home button and tap the Standby op...

Page 13: ...n Opens the list of active alerts The button is only present when an alert is active USB button Opens the USB update page The button is only present when an USB flash drive is detected Edit button Ope...

Page 14: ...ring your favorite page s This button may be hidden See section 6 6 After tapping the Edit button you enter the Edit page To go back to the dashboard tap the back arrow Tap the plus button to add widg...

Page 15: ...n of more items is automatically blocked In total 6 favorite pages can be configured Upon return to the Edit page the selected items appear as widgets An empty bullet is shown at the bottom of the Edi...

Page 16: ...on 6 6 2 Long press the widget you want to move Arrow buttons will appear 3 Move the widget to the required position by tapping the arrow button s 4 When finished first tap the red cross in the top ri...

Page 17: ...button to go to the Edit page This button may be hidden See section 6 6 Tap the widget name to open the Custom name page Make the required change and tap the confirm button Note the customized name w...

Page 18: ...s from the list with an active alarm are accompanied by an alarm symbol 6 3 Device page From the System screen section 6 2 tap on a device to go to the Device page Each device has its own Device page...

Page 19: ...buzzer can sound even if you switched it off in the configuration See section 6 7 You can also create your own alarm messages These alarms have a yellow border See section 6 11 In case an alarm is pr...

Page 20: ...target in the MasterBus events See section 6 7 This means the buzzer can sound even if you switched it off in the configuration On On Off Configuration Enter Pin code to unlock the configuration menu...

Page 21: ...ication is recommended X ranges 1 6 Switch X Maximum 16 characters Devices in list Devices to show in the device list At Selection five selection boxes appear to choose a MasterBus device connected Ex...

Page 22: ...ice to take action due to Event X Choose System dependent Event X Command Event based command Action to be taken by the Event X target Choose System dependent Event X Data Event 1 data controls the Ev...

Page 23: ...Copy lets the status follow the input Copy Invert lets the status follow the opposite of the input Copy is used for dimming too by holding the pulse switch pressed for a longer time Toggle changes th...

Page 24: ...p the confirmation button in the top right corner 6 When all required text lines are entered tap the left arrow button in the top left corner of the screen twice to go to the System page 7 Tap the dev...

Page 25: ...ted and a USB flash drive button appears on the dashboard After the EasyView 5 has been switched off and on the USB button is being shown in the left upper corner of the screen Tap the USB button to g...

Page 26: ...instrument to retrieve historical data of your electrical installation 9 Trouble shooting Contact your local Mastervolt Service Centre if you cannot correct a problem with the aid of the trouble shoo...

Page 27: ...s of the network Check if connected see section 3 3 MasterBus network is configured as a ring network Ring networks are not allowed Check the connections of the network see section 3 3 T connections i...

Page 28: ...me see section 6 6 Wrong language is displayed Wrong setting of the language at the EasyView 5 See section 6 5 for adjustment of the language Wrong setting of the language at one of the connected devi...

Page 29: ...36kg 0 79lbs Dimensions 113 x 127 x 43 mm 4 4 x 5 0 x 1 7 inch Display size 109 mm 4 3 inch Display languages EN NL DE ES IT FR FI SV NO DA RU IP degree IP67 front IP23 back Power supply MasterBus 12V...

Page 30: ...30 EasyView 5 User and Installation Manual 70 97 3 4x Front mounting holes 127 113 82 113 Front Back without wall box...

Page 31: ...EasyView 5 User and Installation Manual 31 43 Case partly removed to show mounting hole details 40 7 9 5 2 Side with wall box Side without wall box...

Page 32: ...rvolt com Location Shipping Power Products LLC N85 W12545 Westbrook Crossing Menomonee Falls Wisconsin 53051 United States Asia Pacific Customer Service T 64 9 415 7261 Option 1 E enquiries bepmarine...