8  TECHNICAL DATA 

Specifications are subject to change without prior notice.

 

8.1 

Specifications inverter 

Model 

12V/2000VA-60A 

24V/2000VA-40A 

12V/3000VA-100A 

24V/3000VA-60A 

Part number/product code 

35012000 

35022000 

35013000 

35023000 

Nominal battery voltage 

12V 

24V 

12V 

24V 

Inverter output voltage 

230V 

230V 

230V 

230V 

Frequency 

50/60 Hz 

50/60 Hz 

50/60 Hz 

50/60 Hz 

Continuous power @Tamb=40˚C 

2000VA 
1600W 

2000VA 
1600W 

3000VA 
2600W 

3000VA 
2600W 

Max. peak load (10sec) 

150% 

150% 

150% 

150% 

Max. peak load (5sec) 

200% 

200% 

200% 

200% 

Output waveform 

pure sine 

pure sine 

pure sine 

pure sine 

Max. efficiency 

93% 

93% 

93% 

93% 

DC input voltage range 

10-16V 

10-16V 

10-16V 

10-16V 

Switch off voltage low battery 

10.2V 

10.2V 

10.2V 

10.2V 

Switch on voltage low battery 

10.5V 

10.5V 

10.5V 

10.5V 

Switch off voltage high battery 

16.0V 

16.0V 

16.0V 

16.0V 

Switch on voltage high battery 

15.0V 

15.0V 

15.0V 

15.0V 

Max. ripple on DC @ full load 

15% 

15% 

15% 

15% 

Nominal DC current at full load 

160A 

100A 

260A 

130A 

Recommended battery capacity 

120 - 600 

80 - 400 

200 - 1000 

120 - 600 

No load DC power consumption 

 

 

 

 

Inverter off mode  
(main switch in position 

<1mA 

<1mA 

<1mA 

<1mA 

Energy saving mode 

10W 

10W 

10W 

10W 

Normal operation mode 

30W 

30W 

30W 

30W 

 

8.2 

Specifications charger 

Model 

12V/2000VA-60A 

24V/2000VA-40A 

12V/3000VA-100A 

24V/3000VA-60A 

Input voltage range 

90-280V; power derating below 170V (50% @ 90V, 100% >170V) 

Max AC input current 

6A 

8A 

10A 

12A 

Max. charge current @Tamb=40˚C 

60A 

40A 

100A 

60A 

Battery temperature sense 

Input present, sensor included 

Battery temperature compensation 

-30mV per °C / -
17mV per °F 

-60mV per °C / -
33mV per °F 

-30mV per °C / -
17mV per °F 

-60mV per °C / -
33mV per °F 

Voltage sense 

No 

Battery types 

Flooded (default) / AGM / Gel / MLI / Constant voltage / User defined 

Charge characteristic 

Mastervolt 3-step+, see the following table 

Flat battery charge 

Yes, reduced (25%) charge current at low (<9V/<18V) battery voltage 

 

Summary of Contents for COMBIMASTER 12V/2000VA-60A

Page 1: ...OMBIMASTER 230V Series INVERTER CHARGER COMBINATION WITH AC IN SUPPORT USER AND INSTALLATION MANUAL 10000015079 03 To download this manual in other languages please visit our website www mastervolt co...

Page 2: ...5 3 AC Safety grounding 10 4 5 4 Network wiring CZone MasterBus 10 4 6 Things you need 10 4 7 Installation step by step 11 4 8 Accessories connector dry contacts 14 4 8 1 Remote switch 14 4 8 2 Alarm...

Page 3: ...ular base at least once a year Do not use the CombiMaster when the wiring is undersized or damaged 6 Do not operate the CombiMaster if it has received a sharp blow been dropped or otherwise damaged in...

Page 4: ...nded limits of discharge level of your batteries 5 If it is necessary to remove a battery always remove grounded terminal from battery first Make sure all accessories are off so as not to cause an arc...

Page 5: ...ply with these instructions may result in under performance damage or failure of the product and may void this warranty The warranty is limited to the cost of repair and or replacement of the product...

Page 6: ...Ground stud 11 CZone MasterBus connection 12 Accessories connector 13 Temperature sensor connection 3 2 Operating modes Inverter mode When there is no external AC power available the inverter provide...

Page 7: ...mote or a Touch 5 in a CZone network Some settings can only be adjusted from a laptop notebook or PC connected to the CombiMaster via a USB Interface 3 4 Protection Overload or short circuit while in...

Page 8: ...ventilation in any way The CombiMaster requires a minimum of 100mm 4 of clearance on every side to ensure safety and proper ventilation If the CombiMaster is installed in the immediate vicinity of liv...

Page 9: ...eline only Always comply with all local rules and regulations WARNING On first connecting to power make sure the CombiMaster is in a well ventilated area as it might spark 4 5 1 DC wiring Always keep...

Page 10: ...Recommended cross section for the AC wiring AC Current Minimum cross section 0 20 A 2 5 mm 20 32 A 4 mm Recommended wire colors refer to local rules Wire color Meaning Must be connected to Europe USA...

Page 11: ...ns Appropriate and reliable cable terminals cable lugs battery terminals and cord end terminals We recommend as a minimum tool kit Socket wrench to fix the main DC cables 13mm Socket wrench to fix the...

Page 12: ...the two screws at the bottom and then lifting the front cover plate Step 7 Connect the AC wiring to the screw terminals Fasten the cables with a strain relief Step 8 Integrate a fuse holder in the po...

Page 13: ...nnect to the CombiMaster Adding the CombiMaster to a MasterBus network 1 Disconnect a MasterBus cable or Terminator from the closest MasterBus device and connect it to the CombiMaster 2 Connect the ne...

Page 14: ...Remote contacts to use the ignition lock In this case the CombiMaster s main switch must be in the off position Closed On Open Charge only Use both contacts to connect an external switch In this case...

Page 15: ...h the DIP switch settings This is done in the CZone Configuration Tool MasterBus network Use an RJ45 MasterBus cable not included and daisy chain the CombiMaster to the other MasterBus devices forming...

Page 16: ...to the ON position 1 DIP switch 2 is MasterBus Powering ON 1 or OFF 0 By default this is OFF DIP switches 3 to 5 are used for battery type selection DIP switch 3 4 5 MasterBus settings Flooded 1 0 0...

Page 17: ...ters as shown in MasterAdjust Menu Description Temperature high Internal temperature of the CombiMaster is too high Fan error An error has been detected in the fan DC high voltage Battery voltage is t...

Page 18: ...Maximum time that the charger stays in absorption phase 240 min 0 600 min Return Amps Return amps of maximum charge current 6 0 100 Float Voltage Float voltage 13 25 26 50V 12 15 24 30V Return to Bul...

Page 19: ...arge phase Absorption Float Charge phase Float AC IN Limit A AC input is set to 6A AC IN Limit B AC input is set to 10A AC IN Limit C AC input is set to 16A Table 2 CombiMaster 230V Series MasterBus E...

Page 20: ...k phase Charger in absorption phase Charger in float phase AC IN support mode Green blinking Inverter power save mode active Red on AC input out of range battery voltage low warning shutdown battery v...

Page 21: ...lk phase Once consumption decreases the charger goes back to normal operation of the 3 step charge system Connected to the CombiMaster the batteries can be left unattended for weeks or months One hour...

Page 22: ...ust be corrected immediately If necessary use a soft clean cloth to clean the CombiMaster Do not use any liquids or corrosive substances such as solvents alcohol petrol or abrasive components 6 6 1 De...

Page 23: ...s the charge current is reduced Check AC input voltage Batteries not fully charged Charge current too low See Charge current too low in this table Current to load is too high Reduce load taken from th...

Page 24: ...0V 16 0V 16 0V 16 0V Switch on voltage high battery 15 0V 15 0V 15 0V 15 0V Max ripple on DC full load 15 15 15 15 Nominal DC current at full load 160A 100A 260A 130A Recommended battery capacity 120...

Page 25: ...ulk time at 13 25 26 50 V 13 25 26 50 V 13 25 26 50 V 13 25 26 50 V Return to bulk voltage 12 80 25 60 V 12 80 25 60 V 12 80 25 60 V 13 25 26 50 V Bulk return time 30 s 30 s 30 s 240 s Absorption volt...

Page 26: ...ty not condensing Standards approvals listings CE E mark Front panel display Yes LEDs show AC input state Inverter state charger state Battery temperature sensor Yes Cooling Maintenance free vario fan...

Page 27: ...allation Manual 27 8 5 Dimensions 12V 2000VA 60A and 24V 2000VA 40A 12V 3000VA 100A and 24V 3000VA 60A Figure 8 Dimensions in mm inches 240 9 5 262 10 3 150 5 9 153 6 0 378 14 9 284 11 2 240 9 5 327 1...

Page 28: ...1 USA 1 800 307 6702 Option 1 technical marinco com ASIA PACIFIC 42 Apollo Drive Rosedale AUCKLAND 0632 New Zealand 64 9 415 7261 enquiries bepmarine com Copyright 2019 Mastervolt All rights reserved...

Reviews: