CombiMaster 230V Series
– User and Installation Manual
13
Step 9.
Attach the battery temperature sensor to the casing of the battery bank. Then plug the temperature sensor cable
into the “temp.sensor” jack.
Note:
Lithium-ion batteries require no temperature sensor.
Step 10.
On the left side of the CombiMaster check the jumper selecting the grounding system.
Step 11.
Option: Connect the CombiMaster to the CZone or MasterBus network. See section 4.9 on page 15 for more
information on system integration.
Adding the CombiMaster to a CZone network
1
Disconnect the backbone at the closest
backbone connection and add in a tee
connector.
2
Reconnect the backbone connection(s) with
the new tee connector in place.
3
Connect the RJ45 CZone/MB drop cable to
the black coupler on the tee and then
connect to the CombiMaster.
Adding the CombiMaster to a MasterBus
network
1
Disconnect a MasterBus cable or Terminator
from the closest MasterBus device and
connect it to the CombiMaster.
2
Connect the new MasterBus cable to the
other MasterBus device and then connect to
the CombiMaster.
Ensure that the network is properly terminated.
Step 12.
Option: use a small screw driver to change DIP switch settings. See section 5.1 on page 16.
Note:
if added to a CZone network, the DIP switches are used to set the
CZone address during configuration.
Step 13.
Option: connect external alarm or remote switch input. See section 4.8.
Step 14.
Set the desired output voltage and other configuration settings using a remote control panel or the DIP switches.
See chapter 5.
Step 15.
Check all wiring. If all wiring is OK: Place the inverter fuse.
WARNING
!
When the fuse is placed, internal capacitors may cause a spark. This is normal
Step 16.
Close the connection compartment and fix the screws at the bottom.
Step 17.
Switch on the CombiMaster.