Parameter
Meaning
Factory
setting
Value range
Bulk
Voltage
Bulk voltage (@ 25
°
C); see section
28.80V
16-32V
Minimum time Minimum time of the Bulk phase
since
Start bulk timer
120sec
0-240sec
Start time at
Battery voltage trigger point to start
the bulk timer
26.50V
(read only)
Maximum
time
Maximum time of the Bulk phase
since
Start bulk timer
480 min
0-1440min
Absorption
Voltage
Absorption voltage (@ 25
°
C); see
section 5.4
28.50V
16-32V
Maximum
time
Maximum absorption timer
240min
0-1440min
Return Amps
Return amps. If the charge current
drops below this level, the charger
switches from the Absorption to the
Float stage (% of I
max
)
6%
0-50%
Minimum time Minimum absorption timer
15min
0-240min
Float
Voltage
Float voltage (@ 25
°
C); see section
26.50V
16-32V
Return to bulk
V
Return to bulk voltage; If the battery
voltage stays below this level for at
least the
Return to bulk delay time,
the charger will start the Bulk stage
25.60V
16-32V
Return to bulk
sec
Return to bulk delay time, see
Return
to bulk voltage
30sec
0-240sec
DC 1 OUT
Name
Name of this output
Output 1
0-16 chars
Shunt device
Selection of the MasterShunt to
which output 1 of the ChargeMaster
Plus is connected
Not selected
Not selected,
MSH + Product Name
DC 2 OUT
Name
Name of this output
Output 2
0-16 chars
Software version
Read-only information about ChargeMaster Plus
version
Not applicable
Not applicable
Installer menu
DIP Switch
DIP switch settings
1100000000
0 / 1
Factory
settings
button
Button to reset the ChargeMaster
Plus to default settings (requires
installer rights)
Not applicable Not applicable
Parameters marked with a